4.3.3. Filter Return Loss test for POTS port :
CPF104IG
Return loss measure the amount of energy that is lost due to reflection which resulted from
impedance mismatching at the interface. Return loss is essentially defined as the ratio of the
power incident upon a given transmission system to the power reflected caused by impedance
mismatch with respect to reference impedance at the interface between source and device.
Return loss figure are a function of the impedance of the circuit involved and are therefore
frequency dependent. These impedance must be closely maintained in order to reduce the
possibility of undesirable reflection and echoes which in long distance circuit the telephone user
or destroy the data being sent. To perform the return loss test ,open ,short, load calibration must
be done prior measurement while the LCZ impedance Analyzer being selected in impedance
mode. Return loss is general expressed in decibels.
General Return loss equation as below:
Return loss = 20 log ZLoad + ZM / ZLoad - ZMdB
Where ZLoad = the reference impedance ZM = the measured impedance
The test setup is shown in drawing below :
ZADSL
Data sheet subject to change without notice
RDPS-POTS434(R0)10/16/2002