CPF104V
4.3.2. Return loss for POTS :
4.3.2.1. Description :
Return loss is essentially defined as the ratio of the power incident upon a given
transmission system to the power reflected caused by an impedance mismatch with
respect to reference impedance at the interface between source and device.Return loss
is generally expressed in decibels. General Return Loss equation as below:
Return loss = 20 log ZR + Z M / ZR - Z M dB
ZR = the reference impedance
ZM = the measured impedance
4.3.2.2. Apparatus :
a . HP 4192A Analyzer or equivalent
b . Complex load ZL = Zcomplex(1) or Zcomplex(2) or Zcomplex(3) or 600ohms
c . Test fixture : HP16047A test fixture
4.3.2.3. Test procedure :
a . Set the measurement Frequency of interest
b . Calibrating the HP4192A L.C.Z. impedance Analyzer via the short . open, load
c . Connecting the Analyzer to the POTS side of splitter with the complex load
across the Line side.
d . Measure the impedance value R + jX and calculate the Return loss expressed in
decibel from the equation Return loss = 20 log ZR + Z M / ZR – Z M dB
e . Change another frequency of interest, then repeat step a~e.
4.3.2.4. Return loss test for one splitter :