DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L6238 데이터 시트보기 (PDF) - STMicroelectronics

부품명
상세내역
제조사
L6238
ST-Microelectronics
STMicroelectronics ST-Microelectronics
L6238 Datasheet PDF : 35 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
L6238
Assuming the motor is stationary, with Output
Enable high and Run/Brake low, the controller is
in the ”Hold for Align & GO” state. When
Run/Brake is brought high, the motor is in align
mode with Phase 1 active (Output A high and
Output B low). Align is a zero. After the align
time-out (user-programmable), the Align bit goes
high and the sequencer double increments the
outputs to Phase 3 (Output B high and Output C
low). After the next time-out, the controller enters
the Go mode, with the sequencer automatically
incrementing the output phase upon detection of
the motor’s Bemf.
Never command an Align & Go unless a refer-
ence signal is present at PLL FREF, since this
is the signal that determines the length of time
that phase 1 remains active.
If Run/Brake is brought low, (or if the 5V supply
is removed) the controller will revert to ”Hold for
Align & GO” and the serial port will be reinitial-
ized. In order to prevent an erroneous restart con-
dition, it is necessary that Run/Brake be held low
until the motor has completely stopped. Once the
motor has stopped, Run/Brake may be brought
high for a complete Align & Go Start-Up routine.
Figure 6: Resync.
2.3 Resynchronization
If power is momentarily lost, the sequencer can
automatically resynchronize to the monitored
Bemf. This resychronization can either occur
whenever Output Enable is first brought low then
high or if the Logic Supply is momentarily lost.
Referring to figure 6, the ”Hold for Resync” state
is entered upon POR (Power On Reset) or when-
ever Output Enable is brought low. The control-
ler leaves this state and enters ”Start Resync”
when Output Enable is high.
If zero crossings are detected, the sequencer will
automatically lock on to the proper phase and
bring the motor speed up to Phase Lock.
This resynchronization will take effect with the
motor speed running as low as typically 30% of
it’s nominal value.
Never command an Align & Go while the mo-
tor is spinning. Always initiate a resync first
or initiate brake mode and allow the motor to
spin down.
ROunuBtErkn=a1=0
P o we r
on
Re s e t
Ho l d
for
”Re s y n c ”
10/35
No Zc
Start
”Resync”
No Zc
R e s y n c =1
Release
min mask
Run

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]