L6238
2.4 Stuck Rotor/Monotonicity
Refer to figure 7. In order to alert the microproc-
essor of fault conditions, two bits are available in
the Serial Port’s Status Register.
1. Stuck Rotor
If the controller enters the Go mode after the Dou-
ble Align, Bemf must be detected within 419ms
when using a system clock frequency of 10MHz.
If this condition is not met, the outputs will be tris-
tated and set this bit to a zero. The controller en-
ters the ”Stuck Rotor Hold” state.
Figure 7: Stuck Rotor/Monotonicity.
OutEna = 1
&
RunBrk = 1
Stuck
Rotor
(hold)
Run
Figure 8: Ext. Sequence.
2. Mono
When the motor spins up normally, the resultant
S P IN SENSE pulses rise in frequency in a
monotonic pattern. Any fault condition that would
cause a rapid decrease in the SPIN SENSE fre-
quency would be detected by internal counters
setting the MONO bit low and forcing a Brake
condition
2.5 External Sequencing
Although the user-defined Start-Up Algorithm is
flexible and will consistently spin up a motor with
minimum external interaction, the possibility ex-
ists where certain applications might require com-
plete microprocessor control of start-up.
The L6238 offers this capability via the SE-
QUENCE INCREMENT input. Referring to figure
9, with Output Enable and Run/Brake low, the
controller is in the ”Hold and Wait for Decision”
state. If the SEQUENCE INCREMENT pin is
brought high during this state, the Auto StartUp
Algorithm is disabled and the sequencer can be
controlled externally.
When Output Enable and Run/Brake are
brought high, the sequencer is incremented every
time that the SEQUENCER INCREMENT pin is
first brought low and then high. During the time
that this pin is high, all Bemf information is
RunBrk = 0
OutEna = 0
SeqInc = X
Auto Start-up
Enabled
D i sab l e d
B r ake
W/Mask
Power
on
Reset
OutEna = 0
&
RunBrk = 0
Hold & wait
for decision
ROuuntBErnka==10
Ho l d
for
”Resync”
Acti on across
line increments
sequencer
RunBrk = 1
OutEna = 0
T r i - st a te
W/Mask
RunBrk = 1
OutEna = 1
Run
W/Mask
SeqInc = 0
SeqInc = 1
SeqInc = 0
SeqInc = 1
T r i - sta t e
W / M ask
RunBrk = 1
OutEna = 0
Run
Wo/Mask
RunBrk = 1
OutEna = 1
Hold for
”Align & Go”
OutEna = 1
&
RunBrk = 0