Absolute Maximum Ratings
Parameter
Ratings
Blocking Voltage
250
Reverse Input Voltage
5
Input Control Current
50
Peak (10ms)
1
Input Power Dissipation 1
150
Total Power Dissipation 2
800
Isolation Voltage, Input to Output 3750
Operational Temperature
-40 to +85
Storage Temperature
-40 to +125
1 Derate Linearly 1.33 mw/˚C
2 Derate Linearly 6.67 mw/˚C
Electrical absolute maximum ratings are at 25°C
Units
VP
V
mA
A
mW
mW
Vrms
°C
°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Output Characteristics @ 25°C
Load Current, Continuous
AC/DC Configuration
DC Configuration
-
IL
-
Peak Load Current
On-Resistance
t=10ms
ILPK
-
AC/DC Configuration
DC Configuration
Off-State Leakage Current
Switching Speeds
IL=50mA
IL=80mA
VL=250V
RON
-
ILEAK
-
Turn-On
Turn-Off
IF=10mA, VL=10V
TON
-
IF=10mA, VL=10V
TOFF
Output Capacitance
50V; f=1MHz
COUT
-
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics @ 25°C
IL=50mA
-
IF=10mA
VR=5V
IF
-
IF
0.4
VF
0.9
IR
-
Input to Output Capacitance
-
CI/O
-
Typ
Max
50
-
80
-
100
50
100
15
30
-
25
-
0.125
5
-
-
10
-
-
1.2
1.4
-
10
3
-
Units
mA
mA
Ω
nA
ms
pF
mA
mA
V
µA
pF