TYPICAL PERFORMANCE
Figures 12 through 15 illustrate the typical analog performance
of the AD1855, at FS = 48 kHz, as measured by an Audio Preci-
sion System Two. Signal-to-Noise and THD+N performance
0
–10
–20
–30
–40
–50
–60
–70
–80
–90
–100
–110
–120
–130
–140
–150
–160
0 2 4 6 8 10 12 14 16 18 20
FREQUENCY – kHz
Figure 12. 1 kHz Tone at –0.5 dBFS (8K-Point FFT)
AD1855
are shown under a range of conditions. Figure 16 shows the
power supply rejection performance of the AD1855. Figure 17
shows the noise floor of the AD1855. The digital filter transfer
function is shown in Figure 18. The two-tone test in Figure 19
is per the SMPTE Standard for Measuring Intermodulation
Distortion.
0
0
–10
–10
–20
–20
–30
–30
–40
–40
–50
–50
–60
–60
–70
–70
–80
–80
–90
–90
–100
–100
–110
–120
–130
–110
–120
–130
–140
–150
–140
–150
–160
–160
0 2 4 6 8 10 12 14 16 18 20
FREQUENCY – kHz
Figure 14. Dynamic Range: 1 kHz at –60 dB
–40
–40
–45
–45
–50
–50
–55
–55
–60
–60
–65
–65
–70
–70
–75
–75
–80
–80
–85
–85
–90
–90
–95
–100
–95
–100
–105
–105
–110
–110
0 2 4 6 8 10 12 14 16 18 20 22
FREQUENCY – kHz
Figure 13. THD+N vs. Frequency at –0.5 dBFS
0
0
–20
–20
–40
–40
–60
–60
–80
–80
–100
–100
–120
–120 –110 –100 –90 –80 –70 –60 –50 –40 –30 –20 –10
AMPLITUDE – dBFS
–120
0
Figure 15. THD+N vs. Amplitude at 1 kHz
REV. B
–11–