TK
DIMENSIONS (mm inch)
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
CAD Data
External dimensions
Standard PC board terminal
4 3.75
.157 .148
3.5
.138
0.25
.010
2.54
.100
10.6
.417
0.5
.020
2.54
.100
9
.354
0.25
.010
7.62
.300
PC board pattern (Bottom view)
5.08
.200
2.54
.100
6-1.0 dia. holes
6-.039 dia. holes
7.62
.300
2.54
.100
Tolerance: ±0.1 ±.004
Self-clinching terminal
4 3.75
.157 .148
3.5
.138
0.25
.010
2.54
.100
10.6
.417
0.5
.020
2.54
.100
9
.354
0.25
.010
7.62
.300
General tolerance: ±0.3 ±.012
Schematic (Bottom view)
Single side stable
1-coil latching
2-coil latching
123
+
123
+
123
+−
+
654
Direction indication
(Deenergized condition)
654
Direction indication
(Reset condition)
654
Direction indication
(Reset condition)
NOTES
1. Packing style
The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
Orientation (indicates PIN No.1) stripe
Stopper (green)
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
9.8 N {1 kgf} or less
Chucking pressure in the direction B:
29.4 N {3 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
A
C
(4)
B
(5)
(6)
23
1
Direction A
mm inch
Direction B Direction C
654
3
.118
6
.236
123
Please chuck the portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.