SPECIFICATIONS (All specifications measured into a 5load connected with 4 feet (~1.2M) 5cable provided with the PVX-2110)
OUTPUT
Output Voltage Polarity
Maximum Value
Minimum Value
Means Of Adjustment
Maximum Output Current
Pulse Rise And Fall Time
Pulse Width
Pulse Recurrence Frequency
(PRF)
Max. Peak Output Power
Max. Average Output Power
Max. Duty Cycle
Droop (At 50A Output Current)
Over/undershoot
Jitter
Output Connector & Cable
INPUT DC VOLTAGE
Input Voltage Polarity
Maximum Value
Minimum Value
Maximum Input Power
Input DC Connector
Positive Or Negative, Factory Configured
200 Volts
0 Volts
Controlled By Power Supply Input Voltage
50A Peak, 25A Average (1)
<100ns (10% to 90%)
<200ns to 2ms, Controlled by Input Gate
Single shot to 50KHz, Controlled by Input Gate
10,000W (2)
5,000W (3)
50%
<5% @ 1ms pulse width, <10% @ 2ms pulse width
<5%
<10ns shot-to-shot
Type N, With 4 feet (~1.2M) 5Coaxial Cable
Positive Or Negative (User-supplied) (4)
200 Volts
0 Volts
5,000W
Type N, Rear Panel
GATE
Gate Source
+5V ±1V into 50
Input Gate Connector
BNC, Front Panel
VOLTAGE & CURRENT MONITORS
Voltage Monitor
Voltage Monitor Connector
50:1 into 50, accuracy typically within 3% of the
actual output voltage
BNC, Front Panel
Current Monitor
Current Monitor Connector
10A/V into 50, accuracy typically within 3% of the
actual output current
BNC, Front Panel
GENERAL
Support Power
90VAC to 240VAC, 50/60Hz
Dimensions (Excluding Connec- 19” W x 5.2” H x 16” D (48.25cm W x 13.2cm H x
tors)
41cm D)
Weight (Approximate)
18 lbs. (8.2 Kilograms)
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
(1) When driving loads with impedances <5, the output voltage must be limited to <200V,
so that the peak output current (V/R) does not exceed 50A, and the maximum average
current (defined as I x Duty Cycle) does not exceed 25A.
(2) Peak output power is defined as V x I during the output pulse.
(3) Average output power is defined as V x I x Duty Cycle.
(4) Input DC power supply must be the same polarity as the PVX-2110 (i.e. a positive output
PVX-2110 requires a positive high voltage DC input).
200ns Minimum Pulse Width, 200V Output
(100ns/Div horizontal scale, 50V/Div vertical scale)
<50ns Rise Time, 200V Output
(25ns/Div horizontal scale, 50V/Div vertical scale)
Typical Output Waveform, 200V
(10µs/Div horizontal scale, 50V/Div vertical scale)
50KHz, 50% Duty Cycle, 200V Output
(8Load, 10µs/Div horizontal scale, 50V/Div vertical scale)
Doc #9200-0216 Rev 3
© Directed Energy, Inc. 2000
Directed Energy, Inc.
An IXYS Company
2401 Research Blvd., Suite 108
Fort Collins, CO USA 80526
970-493-1901 Fax: 970-493-1903
Email: deiinfo@directedenergy.com
Web: http://www.directedenergy.com

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]