DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ASDX001A24R(2008) 데이터 시트보기 (PDF) - Honeywell International

부품명
상세내역
제조사
ASDX001A24R
(Rev.:2008)
Honeywell
Honeywell International Honeywell
ASDX001A24R Datasheet PDF : 4 Pages
1 2 3 4
ASDX Series
TABLE 1. GENERAL SPECIFICATIONS
Supply voltage (Vs)(1)
4.75 Vdc to 5.25 Vdc
Maximum supply voltage(1)
6.50 Vdc (max.)
Consumption current
6 mA (typ.)
Output current (sink)
2 mA (max.)
Output current (source)
2 mA (max.)
Lead temperature
2 s to 4 s at 250 °C [482 °F]
Compensated temp. range
0 °C to 85 °C [32 °F to 185 °F]
Operating temp. range
-20 °C to 105 °C [-4 °F to 221 °F]
Storage temp. range
-40 °C to 125 °C [-40 °F to 257 °F]
Vibration
10 g at 20 Hz to 2000 Hz
Shock
100 g for 11 ms
Life
1 million cycles minimum
Note:
1. The sensor is not reverse polarity protected. Incorrect application of excitation voltage or ground to the wrong pin can cause electrical failure. Application of supply
voltage above the maximum can cause electrical failure.
TABLE 2. PRESSURE RANGE SPECIFICATIONS
Catalog Listing
Pressure Range
Burst Pressure(1)
Sensitivity
ASDX001
0 psi to 1 psi
5 psi
4.00 V/psi
ASDX005
0 psi to 5 psi
20 psi
0.80 V/psi
ASDX015
0 psi to 15 psi
30 psi
0.267 V/psi
ASDX030
0 psi to 30 psi
60 psi
0.133 V/psi
ASDX100
0 psi to 100 psi
150 psi
0.040 V/psi
Note:
1. If the maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture.
TABLE 3. PERFORMANCE SPECIFICATIONS(1)
Characteristic
Symbol
Min.
Typ.
Max.
Unit
Note
Zero pressure offset
Voff
0.420
0.500
0.580
Vdc
Full scale span
Vfss
4.00
Vdc
2
Output at FS pressure
Vfso
4.420
4.500
4.580
Vdc
Accuracy
±2.0
%V
3
Response time
8
ms
4
Quantization step
3
mV
5
Notes:
1. Reference conditions (unless otherwise noted): Supply voltage, V =5.0 ±0.01 Vdc; T =25 °C [77 °F]. Output is ratiometric within the supply voltage range (Vs).
S
A
2. Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure. Span is ratiometric to the supply voltage.
3. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Linearity is the measured deviation based on
a straight line. Hysteresis is the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure. Calibration
errors include the deviation of offset and full scale from nominal values.
4. Response time for a 0 psi to full-scale pressure step change, 10% to 90% rise time.
5. The smallest change in the output voltage, given any change in pressure.
FIGURE 1. BLOCK DIAGRAM
Note:
1. 220 nF capacitor is required between +Vs and GND. 15 nF capacitor between Vout and ground is optional.
2
www.honeywell.com/sensing

Share Link: 