DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ASDX001A24R 데이터 시트보기 (PDF) - Honeywell International

부품명
상세내역
제조사
ASDX001A24R
Honeywell
Honeywell International Honeywell
ASDX001A24R Datasheet PDF : 4 Pages
1 2 3 4
Microstructure Pressure Sensors
0 psi to 1 psi through 0 psi to 100 psi
ASDX Series
FEATURES
ASIC enhanced output
Wide compensated
temperature range 0 °C to
85 °C [32 °F to 185 °F]
Available in absolute,
differential and gage types
Pressure ranges from
0 psi to 1 psi through
0 psi to 100 psi
Accuracy ±2 % max. Volts
Full Scale
Quantization step of 3 mV
Response time 8 ms
TYPICAL APPLICATIONS
Flow calibrators
Ventilation and air flow
monitors
Gas flow instrumentation
Dialysis equipment
Sleep apnea monitoring
and therapy equipment
Barometry
HVAC controls
Pneumatic controls
The ASDX series is an amplified version of Honeywell’s proven performer
and industry leading SDX series sensor. The amplified ASDX sensor’s
footprint is slightly larger than the SDX but it offers a high level output (4.0
Vdc span) on a very cost-effective basis. This series is fully calibrated and
temperature compensated with on-board Application Specific Integrated
Circuitry (ASIC). They are intended for use with non-corrosive, non-ionic
working fluids; such as air and dry gases.
Sensors are available to measure absolute, differential, and gage pressures.
The absolute devices have an internal vacuum reference and an output
voltage proportional to absolute pressure. Differential devices allow
application of pressure to either side of the sensing diaphragm and can be
used for gauge or differential measurements.
All ASDX devices are accurate to within ± 2.0 % full scale, designed for
operation from a single 5.0 Vdc supply and are manufactured in accordance
with ISO 9001 standards.
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only.
Do not use this document as a product installation guide.
Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Sensing and Control