12-Bit Plus Sign Temperature Sensors with
SMBus/I2C-Compatible Serial Interface
A
B
C
D
EF
G
tLOW tHIGH
SMBCLK
SMBDATA
tSU:STA tHD:STA
tSU:DAT
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
Figure 3. SMBus Read Timing Diagram
0.25s ADC CONVERSION TIME
MAX6633/MAX6634/MAX6635
CONVERSION PERIOD 0.5s
MAX6633/MAX6634/MAX6635
H
IJ
K
L
M
I = MASTER PULLS DATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO SLAVE
K = ACKNOWLEDGE CLEAR PULSE
tSU:STO tBUF
L = STOP CONDITION, DATA
EXECUTED BY SLAVE
M = NEW START CONDITION
Figure 4. ADC Conversion Timing Diagram
The Configuration register is 8 bits, read/write, and
contains the SMBus timeout disable bit, fault queue
enable bit, the temperature alarm output polarity select
bits, the interrupt mode select bit, and the shutdown
bit. Registers THIGH and TLOW are 16 bits, read/write,
and contain the values that trigger ALERT. Register
THYST is 16 bits, read/write, and contains the values by
which the temperature must rise or fall beyond THIGH or
TLOW, before ALERT deasserts.
Control Registers (MAX6635)
Seven registers control the operation of the MAX6635
(Figure 7 and Tables 2 through 7). The Pointer register
is the first addressed and determines which of the other
six registers is acted upon. The other six are the
Temperature, Configuration, High-Temperature
(THIGH), Low-Temperature (TLOW), Maximum
Temperature (TMAX), and Hysteresis (THYST) registers.
The temperature value is stored as 12 bits plus a sign
bit, read only, and contains the latest temperature data.
The true register length is 16 bits, with the lower three
used as status bits. The digital temperature data con-
tained in the temperature register is in °C, using a
twos-complement format with 1LSB corresponding to
0.0625°C.
VCC
12 BIT + SIGN
ADC
CONFIGURATION TEMPERATURE
SDA
SCL
SMBus INTERFACE
A0
A1
A2
A3
The Configuration register is 8 bits, read/write, and
contains the SMBus timeout disable bit, fault queue
enable bit, the temperature alarm output polarity select
bits, the interrupt mode select bit, and the shutdown
Figure 5. MAX6633 Functional Diagram
_______________________________________________________________________________________ 7