Temperature Monitor with
Dual Serial Interface
lack the complex logic needed to be a bus master.
Upon receiving an ALERT_ interrupt signal, the host
master can broadcast a receive-byte transmission to
the alert-response slave address (0001 100). Following
such a broadcast, any slave device generating an
interrupt attempts to identify itself by putting its own
address on the bus.
The alert response can activate several different slave
devices simultaneously. If more than one slave
attempts to respond, bus arbitration rules apply, and
the device with the lower address code wins. The los-
ing device does not generate an acknowledge
response and continues to hold the ALERT_ line low
until cleared. Successful completion of the read alert-
response protocol clears the interrupt latch, provided
the condition that caused the alert no longer exists.
Overtemperature Limit Output
OVERT1 asserts when the temperature rises to a value
stored in one of the OVERT1 limit registers (19h and
20h). It deasserts when the temperature drops below
the stored limit, minus hysteresis. OVERT1 can be used
to activate a cooling fan, send a warning, invoke clock
throttling, or trigger a system shutdown to prevent com-
ponent damage.
Command-Byte Functions
The 8-bit command-byte register (Table 3) is the mas-
ter index that points to the various other registers within
the MAX6638. The register’s POR state is 0000 0000,
so a receive-byte transmission (a protocol that lacks
the command byte) that occurs immediately after POR
returns the current local-temperature data.
One-Shot Conversion Cycle
The one-shot command immediately forces a new con-
version cycle to begin. If the MAX6638 receives a one-
shot command while the MAX6638 is in standby mode
(RUN = 1), a new conversion begins, after which the
device returns to standby mode. If during a conversion
the MAX6638 receives a one-shot command, the
MAX6638 ignores the command; however, the results of
the conversion in progress update the data registers
accordingly.
Configuration-Byte Functions
The configuration-byte register (Tables 3 and 5) is a
read-write register with several functions. Bit 7 masks
interrupts. Bit 6 puts the MAX6638 into a standby (STOP)
mode or autonomous (RUN) mode. The MAX6638 enters
standby mode when both SMBus controllers set the cor-
responding configuration bits.
Status-Byte Functions
The status-byte register (Tables 3 and 4) indicates
when any temperature threshold is exceeded. This byte
also indicates whether the ADC is converting and if
there is a fault detected in the external sense diode.
After POR, the state of the flag bits are zero, assuming
no alarm conditions are present. The status byte clears
with any successful read of the status byte, after com-
pletion of a conversion and if the fault condition no
longer exists. Note that the ALERT_ interrupt latch does
not automatically clear when the status-flag bit indicat-
ing the ALERT_ clears.
Registers
The internal registers of the MAX6638 are all 8-bit data
word width and are all accessible through SMBus by
read and write operations.