Temperature Monitor with
Dual Serial Interface
threshold limit values, and control. A standard SMBus
2-wire serial interface is used to read temperature data,
write control bits, and set threshold data. The MAX6638
employs four standard SMBus protocols: write byte, read
byte, send byte, and receive byte (Figure 4).
Read the temperature data from the read internal tem-
perature (00h) and read external temperature (01h)
registers of each SMBus channel. The temperature
data format for these registers is 8 bits for each temper-
ature-sensor channel, with the LSB representing 1°C
(Table 1). The temperature data transmits MSB first.
The external extended-temperature register (10h) pro-
vides additional 3 bits, extending the data to 11 bits
and the resolution to 0.125°C per LSB (Table 2).
The main temperature register and the extended temper-
ature registers update simultaneously upon completion
of a conversion. To ensure the registers contain the
results of the same conversion of the main temperature
data (MSBs) and the extended temperature data (LSBs),
read the data before a new conversion completes.
Alarm-Threshold Registers
Four registers store ALERT threshold values: one high
temperature (THIGH_) and one low temperature
(TLOW_) limit register each for the local and remote
temperature sensors. If either measured temperature
equals or exceeds the corresponding ALERT_ thresh-
old value, the ALERT_ output asserts.
The MAX6638 local ALERT_ THIGH_ register POR state
is 0101 0101, which corresponds to +85°C, while the
remote ALERT_ THIGH_ register POR state is 0101
1111, which corresponds to +95°C. The POR state of
the local and remote TLOW_ registers for all devices is
0000 0000, corresponding to 0°C.
Two additional registers store remote and local alarm
threshold data corresponding to the OVERT1 output
accessible only through SMBus1. The MAX6638 stores
high-temperature thresholds in these registers. If either
of the measured temperatures equals or exceeds the
corresponding alarm threshold value, the OVERT1 out-
put asserts. The MAX6638 local OVERT1 register POR
state is 0101 0101, corresponding to +85°C, while the
remote OVERT1 register POR state is 0111 1101, corre-
sponding to +125°C.
Diode Fault
A continuity fault detector at DXP detects an open cir-
cuit between DXP and DXN, or a DXP short to VCC,
Write Byte Format
S
ADDRESS
WR
ACK
COMMAND
ACK
DATA
ACK
P
7 bits
Slave Address: equiva-
lent to chip-select line of
a 3-wire interface
Read Byte Format
8 bits
Command Byte: selects to
which register you are writing
8 bits
1
Data Byte: data goes into the register
set by the command byte (to set
thresholds, configuration masks, and
sampling rate)
S ADDRESS WR ACK COMMAND ACK S ADDRESS RD ACK DATA /// P
7 bits
8 bits
7 bits
8 bits
Slave Address: equiva-
lent to chip-select line
Command Byte: selects
from which register you
are reading
Slave Address: repeated
due to change in data-
flow direction
Data Byte: reads from
the register set by the
command byte
Send Byte Format
Receive Byte Format
S ADDRESS WR ACK COMMAND ACK P
S ADDRESS RD ACK DATA /// P
7 bits
S = Start condition
P = Stop condition
8 bits
Command Byte: sends com-
mand with no data, usually
used for one-shot command
Shaded = Slave transmission
/// = Not acknowledged
7 bits
8 bits
Data Byte: reads data from
the register commanded
by the last read byte or
write byte transmission;
also used for SMBus alert
response return address
Figure 4. SMBus Protocols