2-Channel Temperature Monitor with Dual,
Automatic, PWM Fan-Speed Controller
(VCC = 3.3V, TA = +25°C.)
Typical Operating Characteristics (continued)
PWMOUT FREQUENCY
vs. DIE TEMPERATURE
35
PWMOUT FREQUENCY
vs. SUPPLY VOLTAGE
35
34
34
33
33
32
32
31
31
30
-40 -15 10 35 60 85 110
TEMPERATURE (°C)
30
3.0 3.5 4.0 4.5 5.0 5.5
SUPPLY VOLTAGE (V)
Pin Description
PIN
TQFN QSOP
1, 15 3, 1
NAME
PWM2,
PWM1
FUNCTION
Open-Drain Output to Power-Transistor Driving Fan. Connect to the gate of a MOSFET or base of a
bipolar transistor. PWM_ requires a pullup resistor. The pullup resistor can be connected to a supply
voltage as high as 13.5V, regardless of the MAX6639’s supply voltage.
2, 16
3
4, 2
TACH2,
TACH1
Tachometer Inputs. Connect to the tachometer output of the fan. TACH_ requires a pullup resistor. The
pullup resistor can be connected to a supply voltage as high as 13.5V, regardless of the MAX6639’s
supply voltage.
5 FANFAIL Active-Low, Open-Drain, Fan-Failure Output. Open circuit when VCC = 0.
4
6
THERM Active-Low, Open-Drain Thermal Alarm Output. Typically used for clock throttling. Open circuit when
VCC = 0.
5
7
OT Active-Low, Open-Drain Overtemperature Output. Typically used for system shutdown or clock
throttling. Can be pulled up to 5.5V regardless of VCC. Open circuit when VCC = 0.
6
8
VCC Power-Supply Input. 3.3V nominal. Bypass VCC to GND with a 0.1µF capacitor.
7
10
GND Ground. Connect to a clean ground reference.
8, 10 9, 12
9
11
DXP1,
DXP2
DXN
Combined Current Source and A/D Positive Input for Remote Diode. Connect to anode of remote-diode-
connected temperature-sensing transistor. Do not leave floating; connect to DXN if no remote diode is
used. Place a 2200pF capacitor between DXP_ and DXN for noise filtering.
Connect Cathode of the Remote-Diode-Connected Transistor to DXN
11
13
ADD
Address Input. Sets device slave address. Connect to GND, VCC, or leave floating to give three unique
addresses. See Table 1.
12
14 ALERT Active-Low, Open-Drain SMBus Alert Output
13
16
SCL SMBus Serial-Clock Input. Can be pulled up to 5.5V regardless of VCC. Open circuit when VCC = 0.
14
15
SDA
SMBus Serial-Data Input/Output, Open Drain. Can be pulled up to 5.5V regardless of VCC. Open
circuit when VCC = 0.