ADVANCED COMMUNICATION & SENSING PRODUCTS
SX1701
Datasheet
5 APPLICATION EXAMPLE
Although intended for differential output operation, the SX1701 may be used for the single-ended output configuration
as shown in Figure 5. Note that some degradation in device performance may be experienced, including a 6 dB
reduction in gain.
5.1 SINGLE-ENDED INPUT TO DUAL DIFFERENTIAL OUTPUTS WITH LOOP-THROUGH SINGLE-ENDED
OUTPUT
+ 5.0 V
10nF
X7R
0603
1nF
X7R
0603
2
1
470pF 17
C0G
0603
SX1701
VDD2
VDD1
GND
75 Ω RF INPUT
0.3pF
C0G
0603
470pF
C0G
0603
3.9nH
wirewound
0603
3 IN
4
DEC
470pF
C0G
0603
G3(1:0)
OUTP3
OUTM3
G2(1:0)
OUTP2
OUTM2
G1(1:0)
OUTP1
OUTM1
75 Ω RF LOOP-
THROUGH OUTPUT
58
6X
3K3
0603
9 12 13 16
470pF
C0G
0603
15
14
470pF
C0G
0603
11
10
470pF
C0G
0603
100 Ω
RF BALANCED OUTPUT 2
470pF
C0G
0603
100 Ω
RF BALANCED OUTPUT1
470pF
C0G
0603
7
6
470pF
C0G
0603
100R
0603
15R0
0603
51R0
0603
Gain control
Figure 5. Dual differential outputs with loop-through.
V1.11_STD – August 20th, 2008
10/13
www.semtech.com