TC74AC540,541P/F/FT
AC Characteristics (CL = 50 pF, RL = 500 Ω, input: tr = tf = 3 ns)
Characteristics
Symbol
Test Condition
Ta = 25°C
Ta =
−40 to 85°C Unit
VCC (V) Min Typ. Max Min Max
Propagation delay
tpLH
time
(Note 2)
tpHL
3.3 ± 0.3 ―
6.8 10.5 1.0 12.0
―
ns
5.0 ± 0.5 ―
4.7 7.0 1.0 8.0
Propagation delay
tpLH
time
(Note 3)
tpHL
3.3 ± 0.3 ―
6.8 11.4 1.0 13.0
―
ns
5.0 ± 0.5 ―
4.7 7.5 1.0 8.5
Output enable time
tpZL
tpZH
3.3 ± 0.3 ―
9.6 15.8 1.0 18.0
―
ns
5.0 ± 0.5 ―
6.4 10.0 1.0 11.4
Output disable time
tpLZ
tpHZ
3.3 ± 0.3 ―
7.7 12.3 1.0 14.0
―
ns
5.0 ± 0.5 ―
6.4 9.2 1.0 10.5
Input capacitance
CIN
―
―
5
10
―
10
pF
Output capacitance
COUT
―
―
10
―
―
―
pF
Power dissipation
capacitance
CPD
TC74AC540
(Note 1) TC74AC541
―
25
―
―
―
pF
―
28
―
―
―
Note1: CPD is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
ICC (opr) = CPD·VCC·fIN + ICC/8 (per bit)
Note 2: For TC74AC540 only
Note 3: For TC74AC541 only
5