Panel Mount Power Supply 5V 35W 1Phase
ENVIRONMENT
Ambient temperature (Operating)
Operating Humidity
Ambient temperature (Storage)
Altitude (Operating)
Shock Test
Vibration (Non-Operating)
Bump
MTBF
Expected Cap Life Time
Material and Parts
Degree of protection
Class of protection
Pollution degree
-10°C to +50°C, with operation to 70°C possible with a linear
derating to half power from 50°C to 70°C.
< 95%RH
-25°C to 85°C
3,000 Meters
IEC60068-2-27, 30G (300m/s2)
IEC60068-2-6, 10Hz to 150Hz @ 50m/s2 (5G peak) for all X,
Y, Z direction
IEC60068-2-29, 11ms/ 10gn
> 700,000 hrs, as per BELL CORE STD or IEC61709
Tested at 115Vac & 230Vac input, 100% load, 25°C ambient
10 years (115Vac & 230Vac, 50% load and 40°C ambient).
RoHS directive, WEEE directive
IPX0
Class I with PE connection
2
Inrush Current
Inrush Current is the first surge current seen on the
input side when AC input is applied to the power
supply. It is the first pulse captured; see a typical
picture for the inrush current as seen in the power
supply.
Start Up Time
Start up time is measured from the point AC input is
applied and the o/p voltage reaches within 90% of its
set value. See picture below for a typical start up time
characteristic of a power supply.
Rise Time
Rise time is the time needed for o/p voltage to rise
from 10% of its set value to 90% of its set value. See
the picture below for a typical rise time measurement
in a power supply.
Hold Up Time
Hold-up time is the duration which output voltage
retains regulation while AC input collapses. Picture
below is a typical hold-up time characteristic.
Output Voltage Adjust
The 5 VDC connection is made using the "+" and "" screw
connections. At the time of delivery, the output voltage is 5
V DC. The output voltage can be set from 4.75 to 5.5 VDC
on the potentiometer seen as Adjust on the front panel of
each power supply.
Dynamic Load
The Power Supply is capable of dynamic output
voltage load change from 2% to 100% within +/-5%
regulation limits. See picture below on the dynamic
behavior the Power Supply.