Testing
14. Testing the Unit
!
CAUTION: MOST PARTS OF THE CIRCUIT CARRY DANGEROUS
VOLTAGES (MAINS) ! OBSERVE ALL SAFETY REQUIREMENTS THAT
MIGHT APPLY !
First, make sure to apply an extra layer of solder on all thinned PCB tracks be-
cause these have to handle high currents.
Connect a light bulb rated for the wall outlet voltage (mains) to LOAD 1.
Insert a dimmer module (K8007) or timer module (K8008) into the first slot (mind
the direction, the components must point to the left).
Connect a 24VAC/300mA source (e.g. transformer) to the 24VAC connector.
LD6 will light.
Connect the 110-240V mains to the SUPPLY Neutral and Live connector. LD7
will light.
WALL OUTLET
24VAC/300mA
TRANSFORMER
DANGER
HIGH
VOLTAGE
24VAC N LOAD1 N LOAD2 N LOAD3 N LOAD4 N LOAD5 N L
24VAC INDICATION
VELLEMAN P8006'1
SUPPLY LD7
LD6
SK1
SK2
SK3
SK4
SK5
1
1
1
1
WALL OUTLET
10
10
10
PUSH BUTTON INPUTS
C 1 C2 C3 C4 C5
C1 2 3 4 5
SW1 SW2 SW3 SW4 SW5
10
C42315
Push button SW1. The module will be activated, and the light bulb will light.
For dimmer/timer module operation details, please check their manuals.
All remaining slots must be tested in the same way. Disconnect the mains
when removing modules or wiring.