DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M61314SP 데이터 시트보기 (PDF) - MITSUBISHI ELECTRIC

부품명
상세내역
제조사
M61314SP Datasheet PDF : 10 Pages
1 2 3 4 5 6 7 8 9 10
MITSUBISHI ICs (MONITOR)
M61314SP
I2C BUS CONTROLLED VIDEO PRE-AMP FOR HIGH RESOLUTION COLOR DISPLAY
SDA, SCL CHARACTERISTIC
parameter
min. input LOW voltage
max. input HIGH voltage
SCL clock frequency.
Time the bus must be free before a new transmission can start.
Hold time start condition.After this period the first clock pulse is generated.
The LOW period of the clock
The HIGH period of the clock
Set -up time for start condition.(Only relevant for a repeated Start condition.
Hold time DATA.
Set-up time DATA
Rise time both SDA and SCL lines.
Fall time both SDA and SCL lines.
Set-up time for stop condition
tR, tF
VIH
SDA
VIL
sy m bol
VIL
VIH
fSCL
tBUF
tHD:STA
MIN
-0.5
3.0
0
1.3
0.6
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
1.3
0.6
0.6
0
100
20+
0.1Cb
20+
0.1Cb
0.6
MAX
1.5
5.5
400
-
unit
V
V
KHz
µs
-
µs
-
µs
-
µs
-
µs
0.9
µs
-
ns
300
ns
300
ns
-
µs
tBUF
VIH
SCL
VIL
tHD:STA
S
tSU:DAT
tHD:DAT
tLOW
tHIGH
tSU:STA
S
tSU:STO
P
S
MITSUBISHI
ELECTRIC
5