M95512-W, M95512-R
10 DC and AC parameters
DC and AC parameters
This section summarizes the operating and measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 8. Operating conditions (M95512-W device grade 6)
Symbol
Parameter
Min.
Max.
Unit
VCC Supply voltage
2.5
5.5
V
TA
Ambient operating temperature (device grade 6)
–40
85
°C
Table 9. Operating conditions (M95512-W device grade 3)
Symbol
Parameter
Min.
Max.
Unit
VCC Supply voltage
2.5
5.5
V
TA
Ambient operating temperature (device grade 6)
–40
125
°C
Table 10. Operating conditions (M95512-R and M95512-DR)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply voltage
TA
Ambient operating temperature
1.8
5.5
V
–40
85
°C
Table 11. AC measurement conditions
Symbol
Parameter
CL
Load capacitance
Input Rise and Fall times
Input Pulse voltages
Input and output timing reference voltages
Min.
Max.
30
50
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Figure 19. AC measurement I/O waveform
Input Levels
0.8VCC
0.2VCC
Input and Output
Timing Reference Levels
0.7VCC
0.3VCC
AI00825B
Unit
pF
ns
V
V
Doc ID 11124 Rev 13