Functional Description
Programming
The HT6P20 is a one time programmable encod-
ing integrated circuit. The programmable codes
consist of 4-bit control codes and 24-bit address
codes. Before using the device, first program the
internal 4 control bits and 24 address bits. Then,
to program the address and control codes, con-
nect the PGM pin to VSS, allowing the SIO pin to
receive control and address codes from the con-
tinuously transmitting programming kit. The
control codes (B0~B3) and address timing are re-
spectively shown on the Table and the Figure for
Programming Timing. In the programming pro-
cess, the mode bit (B0) has to be programmed
first. The 0/2/4/8 data number is selected by the
address along with the data format bits (B1,B2).
The HT6P20, in addition, provides a polarity bit
(B3) to select the polarity of the output data.
Various packages of the HT6P20 offer program-
mable combinations of address/data to meet
various application needs.
B0 B1 B2 B3
P o la r ity c o n tr o l
A d d re s s a n d d a ta fo rm a t
M o d e c o n tro l
HT6P20
Table 1: Control code
· Mode control (B0)
B0
Function
0
Not programmed
1
Programmed
· Address and data format (B1,B2)
B2 B1
Code Format
0
0 A0~A23
0
1 A0~A21 + D1~D0
1
0 A0~A19 + D3~D0
1
1 A0~A15 + D7~D0
· Polarity control (B3)
B3
Data Output Polarity
0
Negative polarity
1
Positive polarity
The HT6P20A/D can be programmed by the
SIO pins. The HT6P20B, on the other hand, is
programmed for 2-data and positive polarity
application.
Programming timing of the HT6P20D (B0~B3=1010)
O SC2
(3 k H z )
PG M
S IO
1 10 100100
1 0XXX X
P r o g r a m m in g
b it
C B0 B1 B2 B3 A0 A1 A2 A3
A 18 A 19 A 20 A 21 A 22 A 23
P r o g r a m m in g
N o te : (1 ) B 0 ~ B 3 a re c o n tro l c o d e s
(2 ) A 0 ~ A 2 3 a re a d d re s s c o d e s
( 3 ) A 2 0 ~ A 2 3 s ta n d s fo r d o n 't c a r e fo r th e H T 6 P 2 0 D
( 4 ) S IO m u s t b e s e t to " H ig h " d u r in g C a n d B 0 p e r io d s
( 5 ) 0 : " L o w " ; 1 : " H ig h " ; X : D o n 't c a r e
Programming timing for the HT6P20D