DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L6260 데이터 시트보기 (PDF) - STMicroelectronics

부품명
상세내역
제조사
L6260 Datasheet PDF : 30 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
L6260
System Control Register A (Reg 3)
Reg: 3
Name: System Control Register A
Type: Write only.
BIT
LABEL
0 SPIN_ENABLE
1 VCM_ENABLE
2 SRESET
3 INCRE
4 RUN_SRCH
5 8_12P
6 BIP_TRIP
7 UNI_TRIP
8 VCMRET
9 SPEED
10 EL_MECH
11 TEST_COUNT_RESET
DESCRIPTION
@POR
Enable spindle functions (1 = enabled; 0 = Disabled). Together
0
with VCM_ENABLE, determine the Normal, Idle or Sleep mode of
operation. See Mode Table for details.
Enable VCM functions (1 = enabled; 0 = Disabled). Together with
0
SPIN_ENABLE, determine the Normal, Idle or Sleep mode of
operation. See Mode Table for details.
Reset spindle state machine (sequencer). 0=Reset. All spindle
0
and FLL registers are also reset. Also used to control the charge
pump (1 = off).
A 0 to 1 transition of this bit increments the spindle state machine. 0
Normally used in SEARCH mode. Must be set to 1 in RUN Mode.
1=Auto-increment enabled (RUN Mode)
0
0 = Auto-increment disabled (SEARCH MODE)
Selects 8/12 pole motor: 1 = 8 pole, 0 = 12 pole
0
Define Tristate, Bipolar, or Tripolar operation:
0
See Spindle Drive Mode Table.
0
Activated VCM Retract: 1 = retract.
0
Programs the Spindle Speed Control Method.
0
SPEED= 0: The L6260 operates open loop, with speed error
sensing performed externally and speed effort written into the
SPIN_DAC.
SPEED = 1: The speed is controlled internally through the built-in
control loop.
Specifies electrical or mechanical cycle for the FLL control.
0
1 = Electrical, 0 = Mechanical
Writing a 0 resets the test sequence. Must be set to 1 to allow
0
ATEST and DTEST functions.
MODE OF OPERATION (REGISTER 3 BITS 0 AND 1)
SPIN_ENABLE
(0) DISABLED
(0) DISABLED
(1) ENABLED
(1) ENABLED
VCM_ENABLE
(0) DISABLED
(1) ENABLED
(0) DISABLED
(1) ENABLED
MODE
SLEEP
NOT NORMAL
IDLE
NORMAL
DESCRIPTION
MINIMUM POWER DISSIPATION.
VCM IS FORCED TO A PARK CONDITION
VCM DISABLED FOR REDUCED DISSIPATION
NORMAL MODE OF OPERATION
SPINDLE DRIVE MODE (REGISTER 3 BITS 6 AND 7)
BIP_TRIP
0
0
1
1
UNI_TRIP
0
1
0
1
SPINDLE DRIVE MODE
TRISTATE
NOT DEFINED
BIPOLAR
TRIPOLAR
11/30