20Watts 3.3V & 5V output Power Supply
Model No.: NAD-20G
Feature:
l 90 to 264Vac universal input range.
l Approval UL, CSA, TUV.
l EMI/RFI meet VDE & FCC limit B.
l Low cost & compact size.
l Input with inlet socket.
l 20 Watts in 109.85×52×32.5 mm size.
l 2 Year Warranty.
Specifications: typical at nominal line, full load at 25° C.
Input Specifications:
General Specifications:
Input voltage: 90 to 264Vac
Efficiency: 70% typical at full load
Input Frequency: 47 Hz to 63Hz
Hold-up time: 15ms @ 115Vac full load
Input inrush current: 20A at 115Vac
40A at 230Vac
Earth leakage: 0.2mA max @ 115Vac
0.4mA max @ 230Vac
Output Specifications:
Output Rating: Vo1: + 5V /2.0A
Vo2: +3.3V/3.0A
EMI/RFI: VDE & FCC Class B limits
Dielectric Withstand:
Input/output: 3000Vac
Input/Ground: 1500Vac
¬Safety Approval: UL UL1950
CSA 22.2-234/950
TUV EN60950
Output Voltage Accuracy: ± 5% max.
Line Regulation: ± 1% max
Switching frequency: 30kHz(Ref)
Load Regulation: ± 3% max.
(Full to half load)
Transient Response: ± 1% max.dev.
(Full to half load) 500uS recovery
Weight: 180g(5.3Oz)
MTBF: 100,000hours(MIL-HDBK-217F)
Environmental Specifications:
Operating temperature: 0 to +50°C
Temperature Coefficient: ± 0.04% /°C Storage temperature: -20 to +85°C
Ripple & Noise: 50mVp-p max
Humidity: 5 to 95 % RH non-condensing
Protections: a. Over voltage protection
b. Over power protection
c. Short circuit protection
Vibration: 2.4G , 5 to 500Hz
Cooling: Free air convection
Note:
1. Vibration test: Three orthogonal axes, random vibration, 10 minutes for each axis.
2. Maximum output power is 20W.
3. At least 20% of load is required to obtain stable regulation.
4. Ripple & noise test method is measured at output terminal across a 0.1uF ceramic cap
& a 10uF tantalum or electrolytic cap in parallel with a 20MHz bandwidth oscilloscope
directly.
¬ Please refer the safety approval status on appendix 1, For latest safety approval status
Please consult YCL or visit" www.ycl.com.tw"