DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ABC400-1024G 데이터 시트보기 (PDF) - Power-One Inc.

부품명
상세내역
제조사
ABC400-1024G
Power-One
Power-One Inc. Power-One
ABC400-1024G Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ABC400-10XXG Data Sheet
Figure 13: Load transient Vo (500μs/div), 8.5A <-> 17A 2A/μs
CH1: Vo (200mV/div) CH2: Io (5.0 A/div)
Figure 14: Load transient Vo (1.0ms/div), 8.5A <-> 17A, 2A/μs
CH1: Vo (200 mV/div) CH2: Io (5 A/div)
7 PROTECTION
Parameter
Conditions / Description
Min Nom Max Unit
F
Input fuses (L only)
Not user accessible, time lag characteristic
8.0
A
ABC400-1012G 14.0
16.0 VDC
Vo ov OV threshold
ABC400-1024G 28.0
32.0 VDC
ABC400-1048G 53
57 VDC
ABC400-1012G 31.5 33.0 39.0
A
Io lim
Current limit
Vi > 90 VAC, -10 °C ABC400-1024G 20.0
21.0 23.0
A
<Ta < 50 °C
ABC400-1048G 8.9
10 11.1 A
TSD
Over temperature on heat
sinks
Automatic shut-down
100
°C
7.1 OVERVOLTAGE PROTECTION
The AC-DC power supply provides a fixed threshold overvoltage (OV) protection implemented with a HW comparator. Once an
OV condition has been triggered, the supply will shut down and latch the fault condition. the latch can be unlocked by
disconnecting the supply from the AC mains only.
7.2 CURRENT LIMITATION
The main output current limitation will decrease with linear derating to 50% at 70 ºC if the ambient (inlet) temperature increases
beyond 50 °C (see Figure 15 ).