Table 4. Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(External Clearance)
Symbol
L(101)
Value
8.3
Minimum External Tracking
(External Creepage)
L(102)
8.3
Minimum Internal Plastic Gap
0.5
(Internal Clearance)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
>175
IIIa
Units
mm
mm
mm
V
Conditions
Measured from input terminals to output terminals,
shortest distance through air
Measured from input terminals to output terminals,
shortest distance path along body
Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter
and photodetector inside the optocoupler cavity
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
Table 5. Absolute Maximum Ratings
Parameter
Symbol
Min.
Max.
Units
Storage Temperature
TS
–55
+125
°C
Ambient Operating Temperature
TA
–40
+105
°C
Supply voltage
Steady-State Input Voltage[1,3]
Two-Second Transient Input Voltage[2]
Digital Input/Output Voltages
Lead Solder Temperature
VDD1, VDD2
–0.5
6.0
V
VIN+, VIN
–2
VDD1 + 0.5
V
VIN+, VIN
–6
VDD1 + 0.5
V
MCLKIN, MDAT
–0.5
VDD2 + 0.5
V
260°C for 10 sec., 1.6 mm below seating plane
Notes:
1. DC voltage of up to –2 V on the inputs does not cause latch-up or damage to the device; tested at typical operating conditions.
2. Transient voltage of 2 seconds up to –6 V on the inputs does not cause latch-up or damage to the device; tested at typical operating conditions.
3. Absolute maximum DC current on the inputs = 100 mA, no latch-up or device damage occurs.
Table 6. Recommended Operating Conditions
Parameter
Ambient Operating Temperature
VDD1 Supply Voltage
VDD2 Supply Voltage
Analog Input Voltage[1]
Notes:
1. Full scale signal input range ±320 mV.
Symbol
TA
VDD1
VDD2
VIN+, VIN
Min.
–40
4.5
3
–200
Max.
+105
5.5
5.5
+200
Units
°C
V
V
mV
5