DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-7970-300E 데이터 시트보기 (PDF) - Avago Technologies

부품명
상세내역
제조사
ACPL-7970-300E
AVAGO
Avago Technologies AVAGO
ACPL-7970-300E Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Table 3. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics [1]
Description
Symbol
Value
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
I-IV
for rated mains voltage ≤ 300 Vrms
I-IV
for rated mains voltage ≤ 450 V rms
I-IV
for rated mains voltage ≤ 600 Vrms
I-IV
Climatic Classification
55/105/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial Discharge < 5 pC
VIORM
VPR
891
1671
Vpeak
Vpeak
Input to Output Test Voltage, Method a
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial Discharge < 5 pC
VPR
1426
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage, tini = 60 sec)
VIOTM
8000
Vpeak
Safety-limiting values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current [2]
Output Power [2]
TS
175
°C
IS,INPUT
400
mA
PS,OUTPUT
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥ 109
Ω
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
application.
2. Safety-limiting parameters are dependent on ambient temperature. The Input Current, IS,INPUT, derates linearly above 25° C free-air temperature at
a rate of 2.67 mA/°C; the Output Power, PS,OUTPUT, derates linearly above 25° C free-air temperature at a rate of 4 mW/°C.
Table 4. Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Symbol Value
L(101) 7.4
L(102) 8.0
0.5
Units
mm
mm
mm
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
>175 V
IIIa
Conditions
Measured from input terminals to output terminals, shortest
distance through air
Measured from input terminals to output terminals, shortest
distance path along body
Through insulation distance, conductor to conductor,
usually the direct distance between the photoemitter and
photodetector inside the optocoupler cavity
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]