DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-054L 데이터 시트보기 (PDF) - Avago Technologies

부품명
상세내역
제조사
ACPL-054L
Avagotech
Avago Technologies Avagotech
ACPL-054L Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Insulation and Safety Related Specifications
Parameter
Minimum External Air
Gap (Clearance)
Minimum External
Tracking (Creepage)
Symbol ACPL-M50L
L(101) 5
L(102) 5
Minimum Internal
0.08
Plastic Gap
(Internal Clearance)
Tracking Resistance
CTI
175
(Comparative Tracking
Index)
Isolation Group
IIIa
ACPL-054L
4.9
4.8
0.08
175
IIIa
ACPL-W50L
ACPL-K54L
8
8
0.08
175
Units
mm
mm
mm
Volts
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along
body.
Through insulation distance conductor
to conductor, usually the straight line
distance thickness between the emitter
and detector.
DIN IEC 112/VDE 0303 Part 1
IIIa
Material Group (DIN VDE 0110, 1/89,
Table 1)
IEC 60747-5-5, IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (Option 060E)
Symbol
Characteristic
Unit
Description
ACPL-M50L/ ACPL-W50L/
054L
K54L
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
I – IV
I – IV
I – III
I – IV
I – II
I – III
I – III
Climatic Classification
55/105/21 55/105/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
VIORM
560
1140
Vpeak
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
VPR
1050
2137
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial discharge < 5 pC
VPR
896
1824
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
VIOTM
6000
8000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current**
Output Power**
TS
150
175
°C
IS, INPUT
150
230
mA
PS, OUTPUT 600
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC 60747-5-5, IEC/EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of PS and IS on ambient temperature.
6

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]