Land Pattern Recommendation
4.4
(0.17)
2.5
(0.10)
1.3
(0.05)
Land Pattern Recommendation (4-pin Configuration)
4.4
(0.17)
1.92
(0.075)
2.5
(0.10)
0.64
(0.025)
2.0
(0.080)
8.27
(0.325)
Dimension in Millimeters (Inches)
0.64
(0.025)
2.0
(0.080)
8.27
(0.325)
Dimension in Millimeters (Inches)
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision).
Note: Non-halide flux should be used.
Regulatory Information
The ACPL-M49T is approved by the following safety regulatory organizations:
UL
Approved under UL 1577, component recognition
program up to VISO=4000 VRMS
CSA
Approved under CSA Component Acceptance Notice #5.
IEC/EN/DIN EN 60747-5-2
IEC 60747-5-5
EN 60747-5-2
DIN EN 60747-5-2
0.64
(0.025)
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics*
Description
Symbol
Characteristic Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
I – IV
I – III
I – II
55/125/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec, Partial discharge < 5 pC
VIORM
VPR
567
1063
Vpeak
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec, Partial discharge < 5 pC
VPR
907
Vpeak
Highest Allowable Overvoltage (Transient Overvoltage tini = 60 sec)
VIOTM
6000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure.
Case Temperature
Input Current
Output Power
TS
175
°C
IS, INPUT
230
mA
PS, OUTPUT 600
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/