DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-P456 데이터 시트보기 (PDF) - Avago Technologies

부품명
상세내역
제조사
ACPL-P456 Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-P456/W456 Option 060)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5=VPR, Type and Sample Test, tm=10 sec,
Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
Safety-limiting values – maximum values
allowed in the event of a failure.
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
ACPL-W456
I – IV
I – IV
I – III
I – III
I – II
55/100/21
2
1140
2138
1824
8000
ACPL-P456
I – IV
I – IV
I – III
I – III
55/100/21
2
891
1671
1425
6000
Unit
Vpeak
Vpeak
Vpeak
Vpeak
TS
175
175
°C
IS, INPUT
230
230
mA
PS, OUTPUT 600
600
mW
RS
>109
>109
:
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
Table 2. Insulation and Safety Related Specifications
Parameter
Symbol ACPL-P456
Minimum External Air Gap
(External Clearance)
L(101)
7.0
Minimum External Tracking
L(102)
8.0
(External Creepage)
Minimum Internal Plastic Gap
0.08
(Internal Clearance)
Minimum Internal Tracking
(Internal Creepage)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
NA
>175
IIIa
ACPL-W456
8.0
8.0
0.08
NA
>175
IIIa
Units
mm
mm
mm
mm
V
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along body.
Through insulation distance conductor to
conductor, usually the straight line distance
thickness between the emitter and detector.
Measured from input terminals to output
terminals, along internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
4