DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-P340-560E 데이터 시트보기 (PDF) - Avago Technologies

부품명
상세내역
제조사
ACPL-P340-560E Datasheet PDF : 19 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-P340/W340 is approved by the following organizations:
UL
Recognized under UL 1577, component recognition program up to VISO = 3750 VRMS (ACPL-P340) and VISO = 5000 VRMS
(ACPL-W340) expected prior to product release.
CSA
CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-2 (Option 060 Only)
Maximum Working Insulation Voltage VIORM = 891 Vpeak (ACPL-P340) and VIORM = 1140 Vpeak (ACPL-W340)
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (Option 060 – Under Evaluation)
Description
ACPL-P340
ACPL-W340
Symbol
Option 060
Option 060
Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
I – IV
I – IV
I – III
I – III
55/100/21
I – IV
I – IV
I – IV
I – IV
I – III
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
Maximum Working Insulation Voltage
VIORM
891
1140
Vpeak
Input to Output Test Voltage, Method b*
VPR
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
1671
2137
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial discharge < 5 pC
VPR
1426
1824
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
VIOTM
6000
8000
Vpeak
Safety-limiting values – maximum values allowed in the event
of a failure.
TS
175
175
°C
Case Temperature
IS, INPUT
230
230
mA
Input Current
PS, OUTPUT
600
600
mW
Output Power
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802.
4

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]