DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-P454-560E 데이터 시트보기 (PDF) - Avago Technologies

부품명
상세내역
제조사
ACPL-P454-560E
AVAGO
Avago Technologies AVAGO
ACPL-P454-560E Datasheet PDF : 9 Pages
1 2 3 4 5 6 7 8 9
Insulation Related Specifications
Parameter
Min External Air Gap
(Clearance)
Min. External Tracking Path
(Creepage)
Min. Internal Plastic Gap
(Clearance)
Tracking Resistance
Isolation Group
(per DIN VDE 0109)
Symbol
L(IO1)
L(IO2)
CTI
W454
Value
8
8
0.08
175
IIIa
P454
Value
7
8
0.08
175
Units Conditions
mm Measured from input terminals to output terminals
mm Measured from input terminals to output terminals
mm Through insulation distance conductor to conductor
V DIN IEC 112/VDE 0303 Part 1
Material Group DIN VDE 0109
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option 060 only)
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage d 150 Vrms
for rated mains voltage d 300 Vrms
for rated mains voltage d 450 Vrms
for rated mains voltage d 600 Vrms
for rated mains voltage d 1000 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec
Partial Discharge < 5 pC,
Symbol
VIORM
VPR
ACPL-W454
I-IV
I-IV
I-III
I-III
I-II
55/100/21
2
1140
2137
ACPL-P454
I-IV
I-IV
I-III
I-III
55/100/21
2
891
1670
Units
V peak
V peak
Input to Output Test Voltage, Method a*
VIORM x 1.5 = VPR, Type and sample test, tm = 60 sec,
Partial Discharge < 5 pC
VPR
1710
1336
V peak
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 10 sec)
VIOTM
8000
8000
V peak
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
TS
175
175
°C
IS,INPUT
230
230
mA
PS,OUTPUT
600
600
mW
RS
d109
d109
:
* Refer to the optocoupler section of the Designer’s Catalog, under regulatory information (IEC/EN/DIN EN 60747-5-2) for a detailed description of