DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACPL-M484-500E 데이터 시트보기 (PDF) - Avago Technologies

부품명
상세내역
제조사
ACPL-M484-500E Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The ACPL-M484/P484/W484 is approved by the following organizations:
IEC/EN/DIN EN 60747-5-5 (Option 060 only)
Approved with Maximum Working Insulation Voltage VIORM = 567 Vpeak for ACPL-M484, VIORM = 891 Vpeak for ACPL-P484
and VIORM = 1140 Vpeak for ACPL-W484
UL
Approval under UL 1577, component recognition program up to VISO = 3750 VRMS File E55361 for ACPL-M484 & ACPL-
P484;
Approval under UL 1577, component recognition program up to VISO = 5000 VRMS File E55361 for ACPL-W484;
CSA
Approval under CSA Component Acceptance Notice #5, File CA 88324.
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-M484/P484/W484 Option 060)
Description
Symbol ACPL-M484 ACPL-P484 ACPL-W484 Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – IV
I – IV
I – III
I – III
I – III
I – II
I – II
I – II
Climatic Classification
55/105/21 55/105/21 55/105/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
2
Maximum Working Insulation Voltage
VIORM
567
891
1140
Vpeak
Input to Output Test Voltage, Method b*
VPR
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
1063
1670
2137
Vpeak
Input to Output Test Voltage, Method a*
VPR
907
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial discharge < 5 pC
1426
1824
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
VIOTM
6000
6000
8000
Vpeak
Safety-limiting values – maximum values allowed in
the event of a failure.
TS
175
175
175
°C
Case Temperature
IS, INPUT
230
230
230
mA
Input Current
PS, OUTPUT 600
600
600
mW
Output Power
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109
>109
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]