ACS710
120 kHz Bandwidth, High-Voltage Isolation
Current Sensor with Integrated Overcurrent Detection
PERFORMANCE CHARACTERISTICS (continued): TA Range K, valid at TA = – 40°C to 125°C, VCC = 5 V, unless otherwise specified
X25CB CHARACTERISTICS
Optimized Accuracy Range1
IPOA
–25
–
25
A
Linear Sensing Range
Noise2
IR
–75
–
VNOISE(rms) TA = 25°C, Sens = 28 mV/A, Cf = 0, CLOAD = 4.7 nF, RLOAD open
–
1
75
A
–
mV
Sensitivity3
Sens
IP = 25 A, TA = 25°C
IP = 25 A, TA = 25°C to 125°C
–
28
–
27.9
–
mV/A
–
mV/A
IP = 25 A, TA = – 40°C to 25°C
–
28.5
–
mV/A
Electrical Offset Voltage
Variation Relative to
VOUT(QBI)4
IP = 0 A, TA = 25°C
VOE
IP = 0 A, TA = 25°C to 125°C
IP = 0 A, TA = – 40°C to 25°C
–
±3
–
mV
–
±12
–
mV
–
±18
–
mV
Total Output Error5
ETOT
Over full scale of IP OA, IP applied for 5 ms, TA = 25°C to 125°C
Over full scale of IP OA, IP applied for 5 ms, TA = – 40°C to 25°C
–
±2.9
–
–
±5.2
–
%
%
1 Although the device is accurate over the entire linear range, the device is programmed for maximum accuracy over the range defined by IPOA .
The reason for this is that in many applications, such as motor control, the start-up current of the motor is approximately three times higher than the
running current.
2 Vpk-pk noise (6 sigma noise) is equal to 6 × VNOISE(rms). Lower noise levels than this can be achieved by using Cf for applications requiring narrower
bandwidth. See Characteristic Performance page for graphs of noise versus Cf and bandwidth versus Cf.
3 This parameter can drift by as much as 2.4% over the lifetime of this product.
4 This parameter can drift by as much as 13 mV over the lifetime of this product.
5 This parameter can drift by as much as 2.5% over the lifetime of this product.