AD1953
ABSOLUTE MAXIMUM RATINGS*
DVDD to DGND . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
ODVDD to DGND . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
AVDD to AGND . . . . . . . . . . . . . . . . . . . . . . –0.3 V to +6 V
Digital Inputs . . . . . . . . . . DGND – 0.3 V to DVDD + 0.3 V
Analog Inputs . . . . . . . . . . AGND – 0.3 V to AVDD + 0.3 V
AGND to DGND . . . . . . . . . . . . . . . . . . . . –0.3 V to +0.3 V
Reference Voltage . . . . . . . . . . . . . . . . . . . (AVDD + 0.3)/2 V
Maximum Junction Temperature . . . . . . . . . . . . . . . . 125rC
Storage Temperature Range . . . . . . . . . . . . –65rC to +150rC
Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300rC/10 sec
*Stresses above those listed under Absolute Maximum Ratings may cause perma-
nent damage to the device. This is a stress rating only; functional operation of the
device at these or any other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Package Characteristics (48-Lead LQFP)
JA (Thermal Resistance
[Junction-to-Ambient])
JC (Thermal Resistance
[Junction-to-Case])
Min Typ Max
76
17
Unit
rC/W
rC/W
PIN CONFIGURATION
48-Lead LQFP
48 47 46 45 44 43 42 41 40 39 38 37
NC 1
MCLK2 2
MCLK1 3
MCLK0 4
AUXDATA 5
MUTE 6
DVDD 7
SDATA2 8
BCLK2 9
LRCLK2 10
SDATA1 11
BCLK1 12
PIN 1
IDENTIFIER
AD1953
TOP VIEW
(Not to Scale)
36 NC
35 AGND
34 VOUTL–
33 VOUTL+
32 AVDD
31 AGND
30 AVDD
29 VOUTR+
28 VOUTR–
27 AGND
26 VOUTS+
25 VOUTS–
NC = NO CONNECT 13 14 15 16 17 18 19 20 21 22 23 24
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although
the AD1953 features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.