ADIS16227
Data Sheet
DATA RECORDING AND SIGNAL PROCESSING
The ADIS16227 provides a number of registers for configuring
its data collection and signal processing operation (see Table 9).
Figure 13 provides a signal flow diagram, which describes many
of these settings.
Table 9. Sampling/Signal Processing Register Summary
Register
Address Description
X_NULL
0x02
X-axis offset correction
Y_NULL
0x04
Y-axis offset correction
For example, set DIO_CTRL[7:0] = 0x2F (DIN = 0xB62F) to
configure DIO2 as a positive external trigger input and
maintain the DIO1 factory default configuration as a positive
busy indicator. In manual mode, the start command triggers a
recording for an averaged FFT and stops after the recording is
complete. In automatic mode, the start command executes a
recording, and a timer continues to trigger recordings based on
the record period setting in REC_PRD (see Table 11).
Z_NULL
0x06
Z-axis offset correction
Table 11. REC_PRD Register Bit Descriptions
REC_FLSH_CNT
FFT_AVG
REC_CNTR
REC_CTRL
REC_PRD
E GLOB_CMD
0x08
0x0E
0x1A
0x1C
0x1E
0x3E
Record, flash write cycle counter
Record, FFT averages
Record, counter
Record, data processing
Record, automatic mode period
Trigger, record commands
The record control register is REC_CTRL (see Table 10), which
provides external controls for sample rates, dynamic range,
T record storage, recording mode, and power management.
Table 10. REC_CTRL Bit Descriptions
Bits Description (Default = 0x1130)
E [15:14] Not used
[13:12] Window setting:
00 = rectangular, 01 = Hanning, 10 = flat top, 11 = N/A
L [11] SR3, fs ÷ 512 (1 = enabled for analysis)
[10] SR2, fs ÷ 64 (1 = enabled for analysis)
[9]
SR1, fs ÷ 8 (1 = enabled for analysis)
[8]
SR0, fs (1 = enabled for analysis)
O [7]
Power-down between each recording (1 = enabled)
[6]
Not used
[5:4] Signal range:
00 = 0 g to 1 g, 01 = 0 g to 5 g, 10 = 0 g to 20 g, 11 = 0 g
S to 70 g
[3:2] Storage method:
00 = none, 01 = alarm trigger, 10 = all, 11 = N/A
[1:0] Recording mode:
B 00 = manual, 01 = automatic, 10 = manual time, 11 = N/A
RECORDING MODES
O REC_CTRL[1:0] provides three modes for triggering: (1) manual,
Bits
[15:10]
[9:8]
[7:0]
Description (Default = 0x0000)
Not used
Scale for data bits
00 = 1 second/LSB
01 = 1 minute/LSB
10 = 1 hour/LSB
Data bits, binary format, range = 0 to 255
RECORDING TIMES
The automatic recording period (REC_PRD) must be greater
than the total recording time. Use the following equations to
calculate the recording time:
Manual time mode
TR = TS + TPT + TST + TAST
FFT modes
( ) TR = N F × TS + TPT + TFFT + TST + TAST
The storage time (TST) applies only when a storage method is
selected in REC_CTRL[3:2]. See Table 10 for more details on
the record storage setting. The alarm scan time (TAST) applies
only when the alarms are enabled in ALM_CTRL[4:0]. See
Table 22 for more details on enabling the alarms.
Table 12. Available Records
Function
Sample Time, TS
Processing Time, TPT
FFT Time, TFFT
Number of FFT Averages, NF
Storage Time, TST
Time (ms)
See Table 15
10.4
26.6
See Table 19
120.0
(2) automatic, and (3) manual time domain. The manual and
Alarm Scan Time, TAST
2.21
automatic modes produce FFT events, which include data
collection, filtering, windowing, FFT analysis, and record
storage (if selected). The manual time domain mode produces
time-domain data in the buffer. All three modes require an
external trigger, using either the SPI interface or one of the
auxiliary digital I/O lines, DIO1 or DIO2. For the SPI external
trigger option, set GLOB_CMD[11] = 1 (DIN = 0x3F08). For
the digital I/O option, use the DIO_CTRL register (see
Table 59) to configure either DIO1 or DIO2 as an external
trigger input.
Rev. B | Page 10 of 24