DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADM690AN 데이터 시트보기 (PDF) - Analog Devices

부품명
상세내역
제조사
ADM690AN
ADI
Analog Devices ADI
ADM690AN Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ADM690–ADM695
+APPLICATION INFORMATION
Increasing the Drive Current
If the continuous output current requirements at VOUT exceed
100 mA or if a lower VCC–VOUT voltage differential is desired,
an external PNP pass transistor may be connected in parallel
with the internal transistor. The BATT ON output (ADM691/
ADM693/ADM695) can directly drive the base of the external
transistor.
+5V
INPUT
POWER
0.1µF
PNP TRANSISTOR
0.1µF
BATTERY
VCC
VBATT
BATT VOUT
ON
ADM691
ADM693
ADM695
When PFO is low, resistor R3 sinks current from the summing
junction at the PFI pin. When PFO is high, the series combina-
tion of R3 and R4 source current into the PFI summing junc-
tion. This results in differing trip levels for the comparator.
+7V TO +15V
INPUT
POWER
R1
R2
+5V
7805
VCC
1.3V
PFI
ADM69x
PFO
R4
TO
µP NMI
R3
5V
Figure 17. Increasing the Drive Current
Using a Rechargeable Battery for Back Up
If a capacitor or a rechargeable battery is used for back up then
the charging resistor should be connected to VOUT since this
eliminates the discharge path that would exist during power
down if the resistor is connected to VCC.
+5V
INPUT
POWER
0.1µF
I = VOUT – VBATT
R
R
0.1µF
RECHARGEABLE
BATTERY
VCC
VBATT
VOUT
ADM69x
Figure 18. Rechargeable Battery
Adding Hysteresis to the Power Fail Comparator
For increased noise immunity, hysteresis may be added to the
power fail comparator. Since the comparator circuit is nonin-
verting, hysteresis can be added simply by connecting a resistor be-
tween the PFO output and the PFI input as shown in Figure 19.
PFO
0V
0V
VL
VIN VH
( ) VH = 1.3V
1+
–R–1
R2
+
–RR–13
( ) VL = 1.3V
1+ –R–1– – –R–1––(5–V––––1–.–3–V–)–
R2 1.3V (R3 + R4)
( ) ASSUMING R4 < < R3 THEN
HYSTERESIS VH – VL = 5V
R––1
R2
Figure 19. Adding Hysteresis to the Power Fail Comparator
Monitoring the Status of the Battery
The power fail comparator can be used to monitor the status of
the backup battery instead of the power supply if desired. This
is shown in Figure 20. The PFI input samples the battery volt-
age and generates an active low PFO signal when the battery
voltage drops below a chosen threshold. It may be necessary to
apply a test load in order to determine the loaded battery volt-
age. This can be done under processor control using CEOUT.
Since CEOUT is forced high during the battery backup mode, the
test load will not be applied to the battery while it is in use, even
if the microprocessor is not powered.
–10–
REV. A

Share Link: 