DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADP120 데이터 시트보기 (PDF) - Analog Devices

부품명
상세내역
제조사
ADP120 Datasheet PDF : 20 Pages
First Prev 11 12 13 14 15 16 17 18 19 20
Therefore, the capacitor chosen in this example meets the
minimum capacitance requirement of the LDO over temper-
ature and tolerance at the chosen output voltage.
To guarantee the performance of the ADP120, it is imperative
that the effects of dc bias, temperature, and tolerances on the
behavior of the capacitors be evaluated for each application.
UNDERVOLTAGE LOCKOUT
The ADP120 has an internal undervoltage lockout circuit that
disables all inputs and the output when the input voltage is less
than approximately 2.2 V. This ensures that the inputs and the
output of the ADP120 behave in a predictable manner during
power-up.
ENABLE FEATURE
The ADP120 uses the EN pin to enable and disable the VOUT
pin under normal operating conditions. As shown in Figure 31,
when a rising voltage on EN crosses the active threshold, VOUT
turns on. When a falling voltage on EN crosses the inactive
threshold, VOUT turns off.
VOUT
EN
VIN = 5V
VOUT = 1.8V
CIN = COUT = 1µF
ILOAD = 100mA
(40ms/DIV)
Figure 31. Typical EN Pin Operation
As shown in Figure 31, the EN pin has hysteresis built-in. This
prevents on/off oscillations that can occur due to noise on the
EN pin as it passes through the threshold points.
The EN pin active/inactive thresholds are derived from the VIN
voltage; therefore, these thresholds vary with changing input
voltage. Figure 32 shows typical EN active/inactive thresholds
when the input voltage varies from 2.3 V to 5.5 V.
ADP120
1.10
1.05
1.00
0.95
EN ACTIVE
0.90
0.85
EN INACTIVE
0.80
0.75
0.70
2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50
VIN (V)
Figure 32. Typical EN Pin Thresholds vs. Input Voltage
The ADP120 utilizes an internal soft start to limit the inrush
current when the output is enabled. The start-up time for the
1.8 V option is approximately 120 μs from the time the EN
active threshold is crossed to when the output reaches 90% of its
final value. The start-up time is somewhat dependent on the
output voltage setting and increases slightly as the output
voltage increases.
6
EN
5
4
3.3V
3
2
1.8V
1.2V
1
0
0 20 40 60 80 100 120 140 160 180 200
TIME (µs)
Figure 33. Typical Start-Up Time