ABSOLUTE MAXIMUM RATINGS
Storage temperature . . . . . . . . .60°C TA +125°C
Ambient operating temperature . .40°C TA +85°C
Ambient relative humidity . . . . . . . . . . . . . 5% to 100%
(noncondensing)
VCCA with respect to AGND . . . . . . . .0.4 V to +7.0 V
VCCD with respect to DGND. . . . . . . .0.4 V to +7.0 V
VCCP with respect to PGND . . . . . . . .0.4 V to +7.0 V
VEE with respect to AGND . . . . . . . . .+0.4 V to 7.0 V
VIN with respect to VCCA. . . . . . . . .+0.4 V to 10.0 V
(VEE = 5 V)
VIN with respect to VEE . . . . . . . . . .0.4 V to +10.0 V
(VCCA = +5 V)
Other pins with respect to DGND1 . . . . .0.4 V to VCC
Total combined C1C5 current per channel:
Source from VCC . . . . . . . . . . . . . . . . . . . . . . . 32 mA
Sink into DGND . . . . . . . . . . . . . . . . . . . . . . . . 24 mA
Latch-up immunity (any pin). . . . . . . . . . . . . . ±30 mA
Stresses above those listed under Absolute Maximum Ratings
may cause permanent device failure. Functionality at or above
these limits is not implied. Exposure to Absolute Maximum
Ratings for extended periods may affect device reliability.
OPERATING RANGES
Commercial (C) Devices
Analog supply . . . . . . . . . . . . . . . . . . . . . . +5.0 V ±5%
VCCA1, VCCA2, or VCCA
Digital supply . . . . . . . . . . . . . . . . . . . . . . +5.0 V ±5%
VCCP, VCCD1, VCCD2, or VCCD
Analog supply VEE1, VEE2 . . . . . . . . . . . . 5.0 V ±5%
PGND, DGND1, DGND2, or DGND . . . . . . . . . . . . 0 V
AGND1, AGND2, or AGND . . . . . . . . . . . . . . . ±50 mV
Ambient temperature . . . . . . . . . . . 0°C TA +70°C*
Ambient relative humidity . . . . . . . . . . . . . 15% to 85%
Operating Ranges define those limits between which the
functionality of the device is guaranteed.
* Functionality of the device from 0°C to +70°C is guaranteed
by production testing. Performance from 40°C to +85°C is
guaranteed by characterization and periodic sampling of
production units.