DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS2890-000 데이터 시트보기 (PDF) - Dallas Semiconductor -> Maxim Integrated

부품명
상세내역
제조사
DS2890-000
Dallas
Dallas Semiconductor -> Maxim Integrated Dallas
DS2890-000 Datasheet PDF : 27 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Figure 13. BUS MASTER WITH DS2480B DRIVER
+5V
BUS MASTER
HOST CPU
serial
port
serial in
serial out
VDD VPP
POL 1-W
RXD NC
TXD GND
DS2480B
to 1-WIRE connection
of DS2890
DS2890
TRANSACTION SEQUENCE
The protocol for accessing the DS2890 via the 1-Wire port is as follows:
Initialization
ROM Function Command
Potentiometer Function Command
Transaction/Data
INITIALIZATION
All transactions on the 1-Wire bus begin with an initialization sequence. The initialization sequence
consists of a reset pulse transmitted by the bus master followed by presence pulse(s) transmitted by the
slave(s). The presence pulse lets the bus master know that the DS2890 is on the bus and is ready to
operate. For more details, see the “1-WIRE SIGNALING” section.
ROM FUNCTION COMMANDS
Once the bus master has detected a presence, it can issue one of the eight ROM function commands that
the DS2890 supports. All ROM function commands are 8 bits long. A list of these commands follows
(refer to Figure 18 and Figure 19 flowcharts):
READ ROM [33H]
This command allows the bus master to read the DS2890’s 8-bit family code, unique 48-bit serial
number, and 8-bit CRC. This command should only be used if there is a single slave on the bus. If more
than one slave is present on the bus, a data collision will occur when all slaves try to transmit at the same
time (open drain will produce a wired-AND result). The resultant family code and 48-bit serial number
read by the master will be invalid.
MATCH ROM [55H]
The match ROM command, followed by a 64-bit ROM sequence, allows the bus master to address a
specific DS2890 on a multi-drop bus. Only the DS2890 that exactly matches the 64-bit ROM sequence
will respond to the following memory function command. All slaves that do not match the 64-bit ROM
sequence will wait for a reset pulse. This command can be used with a single or multiple devices on the
bus.
14 of 27

Share Link: 