Operation Description (Continued)
Protection Circuit
The AP3720 has several self-protective functions
such as over load protection (OLP), open loop
protection, over voltage protection for VCC, thermal
shutdown (TSD). Because these protection circuits
are fully integrated into the IC without external
components, the reliability can be improved without
increasing cost. Once the fault condition occurs,
switching is terminated and the power transistor
remains off. This causes VCC to fall. When VCC
reaches the UVLO stop voltage of 8V, the current
consumed by the AP3720 decreases to the start-up
current (typically 2.5µA) and the current supplied
from the DC link charges the VCC capacitor. When
VCC reaches the start voltage of 20V, the AP3720
resumes its normal operation. In this manner, the
auto-restart can alternately enable and disable the
switching of the power transistor until the fault
condition is eliminated.
Over Load Protection: In this situation, the
protection circuit should be activated to protect the
SMPS. However, even when the SMPS is in the
normal operation, the over load protection circuit can
be activated during the load transition. To avoid this
undesired operation, the over load protection circuit
is designed to be activated after a specified time
(typically 64ms) to determine whether it is a transient
situation or an overload situation. Because of the
cycle-by-cycle current limit, the maximum peak
current through the BJT is limited, and therefore the
maximum input power is restricted. If the output
consumes exceeds this maximum power, the voltage
decreases below the rated voltage. This reduces the
current through the opto-coupler LED, which also
reduces the opto-coupler transistor current, thus
increasing VFB. If VFB exceeds 4.85V and holds the
situation beyond 64ms, the over load protection
circuit is activated.
Open Loop Protection: In this abnormal situation,
OLP or OVP will be activated.
Over Voltage Protection: If the control loop is open,
the current through the opto-coupler transistor
becomes almost zero. Then VFB climbs up to the over
load situation and the over load protection is
activated. But maybe the output voltage exceed the
rated voltage before the over load protection is
activated, resulting in the breakdown of the devices
in the secondary side and the primary side. To
prevent this situation, an over voltage protection
circuit is employed. In general, VCC is proportional to
the output voltage. If VCC exceeds 26.5V, an OVP
circuit is activated resulting in the termination of the
switching operation. To avoid undesired activation of
OVP during normal operation, VCC should be
designed to be below 20V.
Thermal Shutdown
Thermal shutdown is provided by a precision analog
circuit that turns the power transistor off when the
junction temperature exceeds the thermal shutdown
temperature (typically 160ºC). When the junction
temperature drops about the hysteretic temperature,
normal operation resumes.
Jul. 2009 Rev. 1. 0