Micrel
TRUTH TABLE
SY10E212
SY100E212
LOAD
SHIFT
MR
Mode
L
L
L
Load
H
L
L
Hold
X
H
L
Shift
X
X
H
Reset
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
IIH
Input HIGH Current
— — 150 — — 150 — — 150 µA
IEE
Power Supply Current
mA
10E — 80 96 — 80 96 — 80 96
100E — 80 96 — 80 96 — 92 110
Condition
—
—
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
tPLH
Propagation Delay to Output
ps
—
tPHL
CLK
575 800 1025 575 800 1025 575 800 1025
MR
575 800 1025 575 800 1025 575 800 1025
CLK to S-OUT
575 800 1025 575 800 1025 575 800 1025
tS
Set-up Time
D
SHIFT
LOAD
S-IN
ps
—
175 25 — 175 25 — 175 25 —
150 –50 — 150 –50 — 150 –50 —
225 50 — 225 50 — 225 50 —
150 –50 — 150 –50 — 150 –50 —
tH
Hold Time
D
SHIFT
LOAD
S-IN
ps
—
250 25 — 250 25 — 250 25 —
300 100 — 300 100 — 300 100 —
225 0
— 225 0
— 225 0
—
300 100 — 300 100 — 300 100 —
tRR
Reset Recovery
600 350 — 600 350 — 600 350 — ps
—
tskew
Within-Device Skew
— 100 — — 100 — — 100 — ps
1
tskew
Within-Gate Skew
— 50 — — 50 — — 50 — ps
2
tr
Rise/Fall Times
tf
20% to 80%
275 425 650 275 425 650 275 425 650 ps
—
NOTES:
1. Within-device skew is defined as identical transitions on similar paths
through a device.
2. Within-gate skew is defined as the difference in delays between various
outputs of a gate when driven from the same input.
PRODUCT ORDERING CODE
Ordering
Code
Package
Type
Operating
Range
SY10E212JC
J28-1
Commercial
SY10E212JCTR
J28-1
Commercial
SY100E212JC
J28-1
Commercial
SY100E212JCTR
J28-1
Commercial
2