ACX306AK
<Horizontal Shift Register Driving Waveforms>
Item
Symbol
Waveform
HST rise time
HST fall time
trHst
tfHst
HST
10%
90%
trHst
90%
10%
tfHst
HST
∗6
HST data setup time
tdHst
HST 50%
50%
HST data hold time
thHst
HCK1
50% 50%
tdHst thHst
HCKn∗5 rise time
HCKn∗5 fall time
HCK
HCK1 fall to HCK2 rise
time
trHckn ∗5
HCKn
tfHckn
90%
10%
90%
10%
trHckn tfHckn
∗6
to1Hck HCK1 50%
50%
HCK1 rise to HCK2 fall
time
WIDE rise time
WIDE fall time
∗7
WIDE WIDE rise to VCK rise/
fall time
to2Hck
HCK2
50%
50%
to2Hck to1Hck
trWide
tfWide
WIDE
∗6
tdhWide VCK
90%
10%
trWide
90%
10%
tfWide
50%
WIDE pulse width
WIDE
twhWide
50%
50%
twhWide
tdhWide
∗6 Definitions:
The right-pointing arrow ( ) means +.
The left-pointing arrow ( ) means –.
The black dot at an arrow ( ) indicates the start of measurement
∗7 WIDE represents every 1H pulse as shown in Horizontal Timing.
Conditions
• HCKn∗5 duty cycle
50%
to1Hck = 0ns
to2Hck = 0ns
• HCKn∗5 duty cycle
50%
to1Hck = 0ns
to2Hck = 0ns
• HCKn∗5 duty cycle
50%
to1Hck = 0ns
to2Hck = 0ns
tdHst = 333ns
thHst = 0ns
• tdHst = 333ns
thHst = 0ns
–9–