DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

DS28E05 데이터 시트보기 (PDF) - Maxim Integrated

부품명
상세내역
제조사
DS28E05
MaximIC
Maxim Integrated MaximIC
DS28E05 Datasheet PDF : 17 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS28E05
1-Wire EEPROM
Write Memory [55h]
The Write Memory command is used to program one or more contiguous 2-byte segments of a memory page. This com-
mand is applicable only to memory locations that are not write protected. The parameter byte specifies the page and
segment number where the writing begins. The new segment data is transmitted in the sequence B0, B1. Table 2 shows
the how these bytes map to the addressed memory page. The command flow allows writing one or multiple adjacent
segments within a page. To safeguard against transmission errors, the DS28E05 supports read-after-write verification.
In case of data error, the master aborts the command by issuing a 1-Wire reset. To start the transfer to EEPROM the
master must transmit a release byte (FFh). After the programming time is over, the DS28E05 transmits a CS byte. If a
page is in EPROM emulation mode, the new segment data is the bitwise AND of the segment data in memory and the
new data provided with the command.
Write Memory
Command Code
Parameter Byte
Restrictions
Protocol Variations
Error conditions
CS Byte
55h
Target page selection, starting segment number (Table 3).
The memory page must not be write protected.
Writing within a page.
Writing through the end of the page.
Invalid parameter byte.
The memory page is write protected.
AAh = success.
33h = The command failed because the page is write protected.
Table 3. Parameter Byte Bitmap
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
0
PAGE #
SEG #
Note: The bits marked as 0 must be transmitted as 0 for the parameter byte to be valid.
BIT 1
BIT 0
0
Bits 6:4: Memory Page Selection (PAGE #). These bits specify the memory page that is to be written to. Valid memory
page numbers are 000b (page 0) to 111b (page 7).
Bits 3:1: Starting Segment Selection (SEG #). These bits specify the location within the selected memory page where
the writing begins. For pages 0 to 6 valid segment numbers are 000b (start of memory page) to 111b (last segment of
memory page). Valid segment numbers for page 7 are 000b, 001b, and 010b.