DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

GB4550 데이터 시트보기 (PDF) - Gennum -> Semtech

부품명
상세내역
제조사
GB4550
Gennum
Gennum -> Semtech Gennum
GB4550 Datasheet PDF : 5 Pages
1 2 3 4 5
+10V -10V
0.1
0.1
+5V
0.1
SIGNAL IN
FROM
NETWORK
ANALYSER
75
All resistors in ohms,
all capacitors in microfarads
unless otherwise stated.
42
6
*22
1
NON-POLAR
5
D.U.T. 8
7
3
**RCOMP
10n
**CCOMP
1
0.1
4 CLC110 8
5
OUTPUT TO
NETWORK
ANALYSER
10k
-5V
CLOAD
0.1
NOTES: This circuit can be used for Frequency Response, Delay and Differential Gain and Phase measurements.
* This input capacitor must be shorted out when performing Differential Gain and Phase tests.
** RCOMP and CCOMP are only used on GB4550.
Fig. 2 Test Circuit
+10V -10V
0.1
0.1
GX4314
XPOINT
VIDEO OUT 1
42
6
VIDEO
IN
0.1 to 22
1
GB4550
GB4550A
8
NON-POLAR
7
53
*RCOMP
All resistors in ohms,
all capacitors in microfarads
unless otherwise stated.
**10n
*CCOMP
CLOAD
GX4314
XPOINT
GX4314
XPOINT
GX4314
XPOINT
VIDEO OUT 2
VIDEO OUT 3
VIDEO OUT 4
NOTES: In most applications RCOMP and CCOMP will not be needed since the bandwidth depends on the bus capacitance.
In general, the maximum occurs when CLOAD is between 82 pF and 100 pF.
They are used to control the roll-off for higher load conditions.
* Not used on GB4550A.
** The value of this capacitor should be proportional to the input capacitor used.
The value shown is for a 22 µF input capacitor.
Fig. 3 Typical Application Circuit
520 - 34 - 4
4

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]