DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HSP50214 데이터 시트보기 (PDF) - Intersil

부품명
상세내역
제조사
HSP50214
Intersil
Intersil Intersil
HSP50214 Datasheet PDF : 54 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
HSP50214
TABLE 4. HALFBAND FILTER COEFFICIENTS
COEFFICIENTS
HALFBAND #1
HALFBAND #2
HALFBAND #3
HALFBAND #4
HALFBAND #5
C0
- 0.031303406
0.005929947
-0.00130558
-0.000378609
-0.000347137
C1
0.000000000
0.000000000
-0.000000000
-0.000000000
-0.000000000
C2
0.281280518
-0.049036026
-0.012379646
-0.003810883
-0.00251317
C3
0.499954224
0.000000000
-0.000000000
-0.000000000
-0.000000000
C4
0.281280518
0.29309082
-0.06055069
-0.019245148
-0.010158539
C5
0.000000000
0.499969482
-0.000000000
-0.000000000
-0.000000000
C6
- 0.031303406
0.29309082
-0.299453735
-0.069904327
-0.03055191
C7
0.000000000
-0.499954224
-0.000000000
-0.000000000
C8
-0.049036026
-0.299453735
-0.304092407
-0.081981659
C9
0.000000000
-0.000000000
-0.500000000
-0.000000000
C10
0.005929947
-0.06055069
-0.304092407
-0.309417725
C11
-0.000000000
0.000000000
-0.500000000
C12
-0.012379646
-0.069904327
-0.309417725
C13
-0.000000000
-0.000000000
-0.000000000
C14
-0.00130558
-0.019245148
-0.081981659
C15
-0.000000000
-0.000000000
C16
-0.003810883
-0.03055191
C17
-0.000000000
-0.000000000
C18
-0.000378609
-0.010158539
C19
-0.000000000
C20
-0.00251317
C21
-0.000000000
C22
-0.000347137
NOTE: While Halfband filters are typically selected starting with the last stage in the filter chain to give the maximum alias free
bandwidth, a higher throughput rate may be obtained using other filter combinations. See Application Note 9720, “Calculat-
ing Maximum Processing Rates of the PDC”.
Depending on the number of halfbands used, PROCCLK
must operate a some minimum rate above the input sample
rate, FS, to the halfband. This relationship depends on the
number of multiplies for each of the halfband filter stages.
The filter calculations take 3, 4, 5, 6, and 7 multiplies per
input for HB1, HB2, HB3, HB4, and HB5 respectively. If we
keep the assumption that fS is the input sampling frequency,
then Equation 10 shows the minimum ratio needed.
fPROCCLK/fS ([(7)(HB5)(2HB5)+
(6)(HB4)(2(HB4 + HB5))+
(5)(HB3)(2(HB3+HB4+HB5))+
(4)(HB2)(2(HB2+HB3+ HB4+HB5))+
(3)(HB1)(2(HB1+HB2+HB3+HB4+HB5))]/2T
(EQ. 10)
where:
HB1 = 1 if this section is selected and 0 if it is bypassed;
HB2 = 1 if this section is selected and 0 if it is bypassed;
HB3 = 1 if this section is selected and 0 if it is bypassed;
HB4 = 1 if this section is selected and 0 if it is bypassed;
HB5 = 1 if this section is selected and 0 if it is bypassed;
T = number of Halfband Filters Selected. The range for T is
from 0 to 5.
Examples of PROCCLK Rate Calculations
Suppose we enable HB1, HB3, and HB5. Using Figure 16,
HB1= 1, HB3 = 1, and HB5 = 1. Since stage 2 and stage 4
are not used, HB2 and HB4 = 0. PROCCLK must operate
faster than (7x2+5x4+3x8)/8 = 7.25 times faster than fS.
If all five halfbands are used, then PROCCLK must operate at
(7x2+6x4+5x8+4x16+3x32)/32 = 7.4375 times faster than fS.