DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HX6256NSRT 데이터 시트보기 (PDF) - Honeywell International

부품명
상세내역
제조사
HX6256NSRT
Honeywell
Honeywell International Honeywell
HX6256NSRT Datasheet PDF : 13 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
HX6256
ABSOLUTE MAXIMUM RATINGS (1)
Symbol
Parameter
Rating
Min
Max
Units
VDD
Supply Voltage Range (2)
-0.5
6.5
V
VPIN
Voltage on Any Pin (2)
-0.5
VDD +0.5
V
TSTORE
Storage Temperature (Zero Bias)
-65
150
°C
TSOLDER Soldering Temperature (5 Seconds)
270
°C
PD
Maximum Power Dissipation (3)
2
W
IOUT
DC or Average Output Current
25
mA
VPROT
ESD Input Protection Voltage (4)
2000
V
ΘJC
Thermal Resistance (Jct-toCase)
28 FP/36 FP
28 DIP
2
°C/W
10
TJ
Junction Temperature
175
°C
(1) Stresses in excess of those listed above may result in permanent damage. These are stress ratings only, and operation at these
levels is not implied. Frequent or extended exposure to absolute maximum conditions may affect device reliability.
(2) Voltage referenced to VSS.
(3) RAM power dissipation (IDDSB + IDDOP) plus RAM output driver power dissipation due to external loading must not exceed this
specification.
(4) Class 2 electrostatic discharge (ESD) input protection. Tested per MIL-STD-883, Method 3015 by DESC certified lab.
RECOMMENDED OPERATING CONDITIONS
Symbol
VDD
TA
VPIN
VDDRAMP
Parameter
Supply Voltage (referenced to VSS)
Ambient Temperature
Voltage on Any Pin (referenced to VSS)
VDD Turn on ramp time
Description
Min
Typ
Max
4.5
5.0
5.5
-55
25
125
-0.3
VDD+0.3
50
Units
V
°C
V
ms
CAPACITANCE (1)
Symbol
Parameter
CI
Input Capacitance
Typical (1)
5
Worst Case
Min Max
7
CO
Output Capacitance
7
9
(1) This parameter is tested during initial design characterization only.
Units
pF
pF
Test Conditions
VI=VDD or VSS, f=1 MHz
VIO=VDD or VSS, f=1 MHz
DATA RETENTION CHARACTERISTICS
Symbol
Parameter
Typical (1)
Worst Case (2)
Min Max
Units
VDR
Data Retention Voltage
2.5
V
IDR
Data Retention Current
500
300
µA
(1) Typical operating conditions: TA= 25°C, pre-radiation.
(2) Worst case operating conditions: TA= -55°C to +125°C, post total dose at 25°C.
Test Conditions
NCS=VDR
VI=VDR or VSS
NCS=VDD=2.5V, VI=VDD or VSS
NCS=VDD=3.0V, VI=VDD or VSS
4
www.honeywell.com/radhard

Share Link: 