DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ICS307G-03LFT 데이터 시트보기 (PDF) - Integrated Circuit Systems

부품명
상세내역
제조사
ICS307G-03LFT
ICST
Integrated Circuit Systems ICST
ICS307G-03LFT Datasheet PDF : 12 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ICS307-03
SERIALLY PROGRAMMABLE CLOCK SOURCE
Initial Output Frequency
ICS307-03 on-chip registers are initially configured to provide a 1x output clock on the CLK1 output, and 0.5x clock
on CLK2 and CLK3. The output frequency will be the same as the input clock or crystal for input frequencies from
10 - 50 MHz. This is useful when the ICS307-03 needs to provide an initial system clock at power-up.
Determining and Controlling the Output Frequency with VersaClockTM II
The ICS307-03 is directly supported by the ICS provided software called VersaClock II. Complete programming
words for this device can be calculated on any Windows PC by running the VersaClock II software and simple
inputting desired input and output frequencies. Once the software generates an appropriate programming word, it
may then be either copied to the Windows clipboard or even directly programmed into the ICS307-03 via the host
computers parallel port.
For more information on VersaClock II, please visit www.icst.com or send an e-mail to ics-mk@icst.com.
Manually Determining the Output Frequency
The user has full control over the desired output frequency as long as it is operated within the limits shown in the
AC Electrical Characteristics.
The output of the ICS307-03 can be determined by the following equation:
CLK1Frequency
=
InputFre
quen
cy
--------V---------
R OD
Where:
VCO Divider (V) = 12 to 2055
Reference Divider Word (R) = 1 to 2055
Output Divider = values in tables 5, 6, 7
Also, the following operating ranges should be observed.
VCOmin < InputFrequency -V-- < VCOmaxfreq
R
20kHz < I--n----p---u---t---F----r--e----q---u---e----n---c---y- < 100MHz
R
To determine the best combination of VCO, reference, and output dividers, please use the VersaClock II software
mentioned above. If more information is needed, please contact ICS by sending an e-mail to ics-mk@icst.com.
MDS 307-03 C
8
Revision 101705
Integrated Circuit Systems 525 Race Street, San Jose, CA 95126 tel (408) 297-1201 www.icst.com