IDT54/74FCT164245T
FAST CMOS 16-BIT BIDIRECTIONAL 3.3V-TO-5V TRANSLATOR
MILITARY AND COMMERCIAL TEMPERATURE RANGES
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE (A PORT - 3.3V)
Following Conditions Apply Unless Otherwise Specified:
VCC1 = 5V ± 10%, VCC2 = 2.7V to 3.6V; Commercial: TA = –40°C to +85°C, Military: TA = –55°C to +125°C,
Symbol
VIH
VIL
II H
Parameter
Input HIGH Level
(Input and I/O pins)
Input LOW Level
(Input and I/O pins)
Input HIGH Current (Input pins)
Input HIGH Current (I/O pins)
Test Conditions(1)
Guaranteed Logic HIGH Level
Guaranteed Logic LOW Level
VCC1 = Max.
VCC2 = Max.
VI = 5.5V
VI = VCC2
Min.
2.0
Typ.(2)
Max. Unit
5.5
V
–0.5
0.8
V
±5 µA
±15
II L
Input LOW Current (Input pins)
VI = GND
±5
Input LOW Current (I/O pins)
VI = GND
±15
VIK
Clamp Diode Voltage
VCC2 = Min., IIN = –18mA
0.7 1.2 V
VOH
Output HIGH Voltage
VCC1 = VCC2 = Min. IOH = –0.1mA
VCC2–0.2
V
VIN = VIH or VIL
IOH = –3mA MIL.
2.4
3.0
VOL
Output LOW Voltage
VCC2 = 3.0V
VIN = VIH or VIL
VCC1 = Min.
IOH = –6mA MIL.
2.4
3.0
IOH = –8mA COM'L.
IOL = 0.1mA
0.2
V
VCC2 = Min.
IOL = 16mA
0.2
0.4
VIN = VIH or VIL
IOL = 24mA
0.3 0.55
VCC = 3.0V
IOL = 24mA
VIN = VIH or VIL
IOFF
Input/Output Power Off Leakage VCC1 = 0V, VCC2 = 0V, VIN or VO 4.5V
IOS
Short Circuit Current(4)
VCC1 = Max., VCC2 = Max., VO = GND(3)
IO
Output Drive Current
VCC1 = Max., VCC2 = Max., VO = 1.5V(3)
0.3 0.50
±100 µA
–70 –105 –150 mA
–40
–60
–90 mA
VH
Input Hysteresis
150
mV
ICC2L
Quiescent Power Supply Current VCC1 = Max., VIN = GND or VCC2
0.35
ICC2H
VCC2 = Max.
ICC2Z
NOTES:
1. For conditions shown as Max. or Min., use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC1 = 5.0V, VCC2 = 3.3V, +25°C ambient.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. This parameter is guaranteed but not tested.