SY10E452
SY100E452
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = -40°C
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
VBB
IIH
IEE
VCMR
Output Reference 10E -1.43 — -1.30 -1.38 — -1.27 -1.35 — -1.25 -1.31 — -1.19 V
Voltage
100E -1.38 — -1.26 -1.38 — -1.26 -1.38 — -1.26 -1.38 — -1.26
Input HIGH Current
— — 150 — — 150 — — 150 — — 150 µA
Power Supply
Current
10E — 74 89 — 74 89 — 74 89 — 74 89 mA
100E — 74 89 — 74 89 — 74 89 — 85 102
Common Mode Range(1) -2.0 — -0.4 -2.0 — -0.4 -2.0 — -0.4 -2.0 — -0.4 V
NOTE:
1. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the input signals are within the VCMR range
and the input swing is greater than VPP (min.) and <1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
Symbol
Parameter
TA = -40°C
TA = 0°C
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
fMAX
Max. Toggle Frequency 1000 1400 — 1100 1400 — 1100 1400 — 1100 1400 — MHz
tPLH
Propagation Delay to
ps
tPHL
Output
CLK (Diff) 425 600 850 475 600 800 475 600 800 475 600 800
CLK (SE) 375 600 900 425 600 850 425 600 850 425 600 850
MR 375 625 900 425 625 850 425 625 850 425 625 850
tS
Set-up Time, D
175 –50 — 150 –50 — 150 –50 — 150 –50 — ps
tH
Hold Time, D
225 50 — 200 50 — 200 50 — 200 50 — ps
tRR
Reset Recovery Time
750 450 — 700 450 — 700 450 — 700 450 — ps
tPW
Minimum Pulse Width
CLK 400 —
MR 400 —
tskew
Within-Device Skew(1)
— 50
VPP (AC) Minimum Input Swing(2) 150 —
— 400 —
— 400 —
— — 50
— 150 —
— 400 —
— 400 —
— — 50
— 150 —
— 400 —
— 400 —
— — 50
— 150 —
ps
— ps
— mV
tr
Rise/Fall Time
tf
20–80%
250 475 725 275 475 675 275 475 675 275 475 675 ps
NOTES:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Minimum input swing for which AC parameters are guaranteed.
PRODUCT ORDERING CODE
Ordering
Code
SY10E452JC
SY10E452JCTR
SY100E452JC
SY100E452JCTR
Package
Type
J28-1
J28-1
J28-1
J28-1
Operating
Range
Commercial
Commercial
Commercial
Commercial
Ordering
Code
SY10E452JI
SY10E452JITR
SY100E452JI
SY100E452JITR
2
Package
Type
J28-1
J28-1
J28-1
J28-1
Operating
Range
Industrial
Industrial
Industrial
Industrial