Dimensions LA 200-P (in mm. 1 mm = 0.0394 inch)
Bottom view
Left view
Standard 00
or N° SP..
swiss
made
year week
Secondary terminals
Terminal - : supply voltage - 12 .. 15 V
Terminal M : measure
Terminal + : supply voltage + 12 .. 15 V
Terminal : NC
Connection
Front view
Mechanical characteristics
•General tolerance
•Primary through-hole
•Fastening & connection of primary
Recommended PCB hole
•Supplementary fastening
Recommended PCB hole
Recommended screws
LEM code
± 0.2 mm
17 x 11 mm
4 pins 0.63 x 0.56 mm
0.9 mm
2 holes ∅ 1.75 mm
2.4 mm
K A 22 x 6
47.30.60.006.0
Remarks
•IS is positive when IP flows in the direction of the arrow.
•Temperature of the primary conductor should not exceed
90°C.
•Dynamic performances (di/dt and response time) are best
with a primary bar in low position in the through-hole.
•In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.